Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation material, liquid waste and gas waste. GB18484-2001. The animal/pet combustion speed around 2/3 of average power.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time daily is about 16 hours. The lifetime of incinerator between 5-10 year according to use.
Generally, we proposal little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please compute the waste output capacity around 2kgs per people each day. If there are 200 sickbed in the hospital, that's mean you need one incinerator capacity around 400kgs each day, change to power per hour is around 30-40 kgs per hour. According the operation time daily, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We supply all documents and incinerators simple to setup and operation. Customer can send people come to our factory to find out installation and operation. Generally, we don’t send engineer to local site or even request. The dispatch cost is additional according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi level. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control mode is common control instance. PLC mode according to model and order.
Q: Operation and maintenance costs A: Operation price according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 device incinerators. Incinerators italy for medical waste, incinerators medical waste, incinirator, industrial incinerators china, insenorator, klarge backyard incinerator, laboratory animal incinerator auction, The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to functionality consumer guider, and understand risk of medical waste to protect worker self with necessary security element.
Q: The Residency time in secondary combustion chamber A: 02 sec.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |