Product Description
Technology Respond(FAQ)
Q: What is kind of waste can use in this equipment? A: This gear for medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time daily is about 16 hours. The lifetime of incinerator between 5-10 year according to use.
Generally, we proposal small lab, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please compute the waste output capacity around 2kgs per people each day. If there are 200 sickbed in the hospital, that's mean you need 1 incinerator capacity around 400kgs each day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time daily, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Testing and Assembly A: We provide all documents and incinerators simple to setup and operation. Client can send people come to our factory to find out operation and installation. Small scale medical waste incinerator, syc-30 incinerator, waste incinerator manufacturer China, Generally, We do not send engineer to local site or even request. The dispatch cost is extra according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control manner is common control instance. PLC mode according to order and model.
One individual can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know risk of medical waste to safeguard worker self with necessary protection component.
Q: The Residency time in secondary combustion chamber A: 02 sec.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |