Capacity of destruction in weight: 60 Kg/h.
it ought to be able to operate not less than 10 hours/day
This incinerator has to be able to destruct all combustible wastes produced by hospitals, private practices, laboratories, institutes, etc…
Design Specification: Types A, B, C, D, and E of medical waste
“PYROLYTIC” combustion, by controlling the gasification of waste.
The incinerator should avoid the discharge of black smoke and fine dust, (Smokeless) during the loadings.
it ought to be able to decrease the volume of wastes by 98%.
it ought to be able to hold emission in the second burn with gasoline residence of less than 2 seconds.
The incineration should be completely free from visible smoke in addition to offensive odours.
The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
The Temperatures of combustion: Minimum will be 850oC and max 1400oC
Post combustion: 1100oC.
The Inner diameter of the Chimney: Ø 400 and its elevation: 8 m
The Volume of the combustion chamber: 1.200 L
The Dimension of the door for loading in cm: 70×70.
Burner operation should be Automatic On/Off
Fuel: petrol
The provider must provide necessary information for the best of the installation
This incinerator with”PYROLYTIC” combustion should have:
A combustion chamber of waste:
* Perfectly tight door for the manual loading of waste. The loading should be Manual, Batch Load
* A burner of light that the use is restricted to the ignition of waste.
* Frontage of loading door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating from refractory.
* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminium and insulates bricks to be able to assure a minimum temperature on the outside sheet metal.
* Composition of the refractory;
Refractory concrete :
. Thickness : ≥100 mm
. Nature: 42% of Al203
Insulate in fibrous panels:
. Thickness: ≥75 mm
Nature: Calcium silicate.
* Burner of light of waste, with gas, regular mono-bloc casting directing stirring flame, lighting and safety of electronic ignition, permanent venting, electromagnetic sluice gate of regulation and isolating valve.
* Plate of combustion in Carborundum, preventing the fixing of glass and slags.