Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can use within this equipment? A: This gear for medical waste, pet animal, Municipal waste, live squander. Prohibit any explosive and radiation substance, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion speed around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The lifetime of incinerator between 5-10 year according to use.
Generally, we proposition small lab, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please compute the waste output capacity around 2kgs per people per day. If there are 200 sickbed at the hospital, that's mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Testing and Assembly A: We provide all documents and incinerators easy to installation and operation. Client can send people come to our factory to learn operation and installation. Generally, We do not send engineer to local site or even request. The dispatch cost is extra according to order. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control case. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according version, use situation.
One individual can service 02 unit incinerators. The team should have basic electrician incinerator 50 kg, incinerator 500 kg, incinerator creature, incinerator burner, incinerator burner version for cremation croupes, incinerator catalogue, incinerator combustion capacity, knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and understand risk of medical waste to protect worker self with necessary protection element.
 Q: The Residency time in secondary combustion chamber 
 A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) | 
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour | 
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg | 
| Control Mode | PLC | PLC | PLC | PLC | PLC | 
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L | 
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm | 
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L | 
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes | 
| Feed Mode | Manual | Manual | Manual | Manual | Manual | 
| Voltage | 220V | 220V | 220V | 220V | 220V | 
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw | 
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 | 
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 | 
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes | 
| Temperature Protection | Yes | Yes | Yes | Yes | Yes | 
| Oil Tank | 100L | 100L | 100L | 100L | 200L | 
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm | 
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg | 
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm | 