Together with the following technical information:
1. 1 pharma solid waste incinerator unit comprising two combustion chambers and based on steel base with scrubbing
system.
2.
3. Capacity: Approximated 150 kg/hr. Over 10 hrs.
4. Wastes features:
· BULK density: 70 — 100 kg/ bm³.
· Calorific value: 2000-3000 kcal / hr.
· Moisture content: 20-30%by weight.
· Ash content: 2 — 8 percent by weight.
· Vinyl content: 15-20 percent by weight.
5. Two combustion chambers.
6. Operating temperatures:
· First room: less than 700 – 800 °c.
· Second room: less than 1200 °c (during continuous operation).
7. The burners should be automatically switched off if any of the combustion chambers doors is open.
8. The burners of the first and second combustion chambers are chosen for burning diesel oil (light fuel).
9. Automatic loader and unloader to be supplied.
10. Exhaust gases to be comply with International Environmental code and requirements.
Including:Incinerator: Construction to be specified
The mark to be given
Aspiration: natural
– A getting cage for biomedical waste;
– A combustion chamber with a chimney using a filter to retain the ashes;
Chimney section: approximately 300 cm; using a minimum height of 6 m
Door dimensions: approximately 50×60 cm