small scale incinerator


Manufacturer to provide  necessary information for the best of  the setup

The control panel shall have all appropriate audible and visual alarms to ensure safe performance.

This incinerator with”PYROLYTIC” combustion must have:
A timer with adjustable temporization for the regulation of every burner.
?
? Nature: Calcium
OA burner of lighting that the use is limited to the ignition of waste.
OComposition of the refractory;
Electric box

The secondary combustion chamber must destroy the contaminant merchandise and must resist to high temperature(1100 °C)

Process Filtering system: Scruber to be mentionned as optional

A room of post combustion of gases
OElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and adhering to the control of the automatic cycle.
? Burner of light of waste, with fuel, standard mono-bloc casting guiding  plunging flame, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
. Nature: 42 percent of Al203
A regulator with digital watching for the temperature of combustion.
OBurner with fuel, mono-bloc casting directing type with flat flame, lighting and security of electronic ignition, permanent venting, electromagnetic sluice gate of regulation and isolating valve.
OThe insulation of the combustion chamber ought to be composed of refractory bricks, having a high content of aluminum and insulates bricks in order to guarantee a minimum temperature on the exterior sheet metal.
? Nature: 65% of Al203
? Thickness: ≥85 mm
OCarcass in strong sheet steel with support of connection.
oA burner of combustion of gases,

Incinerators Biological waste disposal system (incinerator)

Incinerator must satisfy the following specifications:

–       Combustion capacity (kW) = 581 +/-10%

–       Combustion capacity (kcal/h) = 500,000 +/-10%

–       Max. . 50% water content) = 100 +/-10%

Further specifications will be supplied with the inquiry.

The incinerator shall be fully self contained.

The incinerator plant shall incorporate a control panel for its own operation. On the control panel we shall have a visual display of the room temperatures. This visual display must control and monitor the incinerator along with his performance.

Ability of destruction in weight shall be 60 Kg/h.

It should be able to operate not less than 10 hours/day

This incinerator must have the ability to destruct all combustible wastes produced by hospitals, private practices, laboratories, institutes, etc…

Design Specification: Types A, B, C, D, and E of medical waste

“PYROLYTIC” combustion, by controlling the gasification of waste.

The incinerator must prevent the discharge of black smoke and fine dust, during the loadings.

It shall have the ability to decrease the quantity of wastes by 98%.

It shall have the ability to hold emission in the next burn with gas residence of less than two seconds.

The incineration should be wholly free from visible smoke as well as offensive odours.

1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.

the principal combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a comprehensive layer of hote face refractory and high efficiency insulation.

The Internal diameter of the Chimney at least: ? 400 and its height: 8 m

The loudness of the combustion chamber at least: 1.200 L

The Dimension of the door for loading in cm : 70×70.

Burner operation should be Automatic On/Off
? Insulate in fibrous panels :
OFrontage of loading door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
OA secondary injection of air to ensure perfect oxygen content.

A control box ensuring the whole cycle of combustion.
1. A combustion chamber of waste:
. Thickness    : ≥100 mm
o Composition of the refractory;

? Refractory concrete :
Controls and regulations:
?
Control box watertight into dust, such as:

A switch circuit breaker for each engine (ventilators and burners).
OPerfectly tight doorway for the manual loading of waste.
OA sheath of evacuation of the gases burnt.
A regulator with digital watching for the temperature of post combustion.
OA device of injection of air allowing a total recombustion of gases,

Process Filtering system: Scruber to be mentionned as optional