Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
50 Kg Per Hour Incinerator
Basic Info.
Additional Info.
Product Description
Nanjing Clover Medical Technology Co., Ltd..
| Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
| Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
| Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
| Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
| Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
| Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
| External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
| Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
| Oil Tank(Liters) | 50 | 100 | 100 | 150 |
| Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
| Chimney (M) | 5 | 5 | 5 | 5 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |
Application Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
Infectious Waste Incinerators
Basic Info.
Additional Info.
Product Description
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *according to order * High temperature, long life of incinerator. * Free or minimum installation on site. * High burn speed, from 10kgs to 500kgs per hour, up to 6ton per day. * PLC Control Plane. *based on order * New Design for pet animal cremation company. * One year warranty on incinerator and parts in stock.
Program Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
Large Capacity Animal Pet Cremation HICLOVER Model A1500 with E-Power Auto.Door
|
|
Model |
|||||
|
A1500 |
Internal Dimensions |
|||||
|
150 x 100 x 96cm |
Suit for Animal |
Cat – yes |
Dog – yes |
Pig – small |
||
|
Cow – small |
Main Product List |
|||||
|
Primary Combustion Chamber |
||||||
|
Secondary Combustion Chamber |
||||||
|
Mix-Combustion Chamber |
||||||
|
Smoke Filter Chamber |
||||||
|
Incinerator Control Case Chimney:10.0Meters |
||||||
|
*(upgrade to Stainless Steel, free cost) |
||||||
|
Italy oil/gas burner: 03 sets |
||||||
|
Oil Tank (if oil fuel): 500Liters |
Layout for Pets Cremation Business |
Movable platform & Automobile. |
||||
|
|
Independent Position for Small Pet |
|||||
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
SWRHA chairman: Delay in Charge causes medical waste Backup
Chairman of the South West Regional Health Authority (SWRHA) Dr Lackram Bodoe said a back-up of medical waste at the San Fernando General Hospital had to do with a delay in payment to a contractor and not the malfunctioning of the incinerator.
Responding to complaints about the risks posed by the accumulated medical waste, which comprised amputated limbs, needles, and bloodstained items, Bodoe assured that the $9 million incinerator installed last year was working well.
He said it had been allowed to accumulate because daily paid employees refused to work on Tuesday.
Speaking with members of the media at SWRHA’s symposium on leadership at the Southern Academy of Performing Arts on Wednesday, Bodoe said:
“I want to provide the assurance that the incinerator itself is working nicely.
“This is a new incinerator that was installed last year and the issue had to do with a contractor who was supposed to eliminate the garbage and there was a delay of funding and that’s what created a temporary situation ”
Asked how soon the situation will be rectified, he said:”I’ve only been given the assurance by the CEO that the matter is being dealt with as we speak, so I expect by the end of the day it will be sorted out.”
Additionally, Bodoe said the SWRHA was also considering introducing a new kind of technology, called the radio wave technology for incineration, which was much more atmosphere friendly.
However, a Public Service Association representative, who wished to remain anonymous, said the incinerator was breaking down on a regular basis because it was installed last year and was not working at this time.
“They even had to revert to the old incinerator and that’s dangerous and unhealthy to people operating that incinerator.
He said employees took the action on Tuesday because since last week they had been assured that the garbage problem could have been sorted out.
Diesel Oil Fired Medical Waste Incenerator 50kg/Hr
Basic Info.
Product Description
Nanjing Clover Medical Technology Co., Ltd..
| Items | Specification | |||
| YD Model | YD-30 / YD-50 / YD-100 / YD-150 / YD-200 / YD-300 / YD-500 / YD-600 | |||
| Main Product List | Primary Combustion Chamber | |||
| Secondary Combustion Chamber | ||||
| Mix Combustion Chamber | ||||
| Smoke Filter Chamber | ||||
| Incinerator Common Control Case | ||||
| Stainless Steel Chimney | ||||
| Italy oil/gas burner: 02 units | ||||
| Oil Tank (if oil fuel) | ||||
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *according to order * High temperature, long life of incinerator. * Free or minimal installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. * PLC Control Plane. *based on order * New Design for pet animal cremation business. * One year warranty on incinerator and components in stock.