Doubel Combustion Chamber

All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.

Read More

High Temperature Incineration

Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.

Read More

Get Lastest News

There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation

Read More

Nanjing Clover Medical Technology Co.,Ltd.

Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201

Latest Product

Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.

Latest Post

Incinerator


Basic Info.

Model NO.:10 kg per hour
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Items/Model TS10(PLC)
Burn Rate 10 kg/hour
Feed Capacity 20kg
Control Mode PLC
Combustion Chamber 100L
Internal Dimensions 50x50x40cm
Secondary Chamber 50L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) 5.4–12.6
Gas Consumption (m3/hour) 6.2–11.4
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 30x30cm
Chimney 3Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800 degree –1000 degree
2nd. Chamber Temperature 1000 degree -1200 degree
Residency Time 2.0 Sec.
Gross Weight 1500kg
External Dimensions 140x90x120cm
 

Nanjing Clover Medical Technology Co., Ltd..

Medical Incinerator


Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Q: What is kind of waste can use in this equipment?  A: This gear for medical waste, pet animal, Municipal waste, reside waste. Prohibit any explosive and radiation material, liquid waste and gas waste. 

Q: Incinerator Smoke Standard  A: China Government Standard: No. GB18484-2001. 

Q: Treatment capacity  A: Typical Ability calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion rate around 2/3 of average power. 

Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time for feeding waste. Burning incenrator manufactuer, burning medical waste, burning waste space, purchase a portable crematorium, purchase a small incinerator, purchase animal cremation systems, Actual combustion time per day is about 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposal small lab, small clinic use capability under 20 kgs per hour. When incinerator use in hospital, please compute the waste output capacity around 2kgs per people each day. If there are 200 sickbed in the hospital, which 's mean you need one incinerator capacity around 400kgs each day, change to power per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator.  *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Testing and Assembly A: We provide all documents and incinerators easy to installation and operation. Client can send people come to our factory to learn installation and operation. Generally, we don’t send engineer to local site if not ask. The dispatch cost is extra according to order. 

Q: Combustion Temperature  A: The first combustion chamber: 800-1000 centi level.  The second combustion chamber: 1000-1200 centi level. 

Q: Incinerator Control Mode  A: Default Control mode is common control instance. PLC mode according to model and order. 

Q: Operation and maintenance costs  A: Operation price according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according version, use situation. 

One individual can service 02 device incinerators. The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and understand risk of medical waste to safeguard worker self with essential protection element. 

Q: The Residency time in secondary combustion chamber  A: 02 sec.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Incinerator


Basic Info.

Model NO.:20 kg per hour
Pullution Sources:Solid Waste Processing
Processing Methods:Combustion
Export Markets:Global

Additional Info.

Trademark:clover

Product Description

Clover provide medical waste incinerators, animal and pet cremators, other solid waste incinerators to over 30 countries. We have re-designed the incinerators lining configuration. We have also designed and installed our very own PLC computer system into incinerator operation system. Medical incinerastor installation costs, medical inciné Rateurs in china, medical incineration, medical incineration container, medical incineration in china, Clover understand it is essential that build them better, keep it simple and offer a great service. We create quality products that give excellent payback on investment, our incinerators will be the most robust and thermally efficient in the industry.  The incinerator lines have small scale to large scaleup to 500kgs per hour. The combustion chamber use high strength material, expensive cost but better quality than competitors. Incinerator operation system use PLC program control mode, give up the complex manual operation.  Thank you for the support,

Items/Model TS20(PLC)
Burn Rate 20 kg/hour
Feed Capacity 40kg
Control Mode PLC
Combustion Chamber 210L
Internal Dimensions 65x65x50cm
Secondary Chamber 110L
Smoke Filter Chamber Yes
Feed Mode Manual
Voltage 220V
Power 0.5Kw
Oil Consumption (kg/hour) 7.8–16.3
Gas Consumption (m3/hour) 8–15.7
Temperature Monitor Yes
Temperature Protection Yes
Oil Tank 100L
Feed Door 45x40cm
Chimney 3Meter
Chimney Type Stainless Steel
1st. Chamber Temperature 800 centi-degree –1000  centi-degree
2nd. Chamber Temperature 1000 centi-degree -1200 centi-degree
Residency Time 2.0 Sec.
Gross Weight 2200kg
External Dimensions 160x110x130cm
 

Incinerator USA Pharmaceutical


Basic Info.

Model NO.:incinerator supplier in saudi arabia
Export Markets:Global

Product Description

Key Features:  * All versions with Dual combustion chamber.  * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator.  * Free or minimum installation on site.  * High burn rate, from 10kgs to 500kgs per hour, cremation equipment available in china, cremation equipment factory china, cremation furnace,  * PLC Control Plane. *according to order  * New Design for pet animal cremation business.  * One year warranty on incinerator and components in stock.  Program Scope:  1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine.  2. 3. Community & Sea Port & Station: Cremation in china, cremation incinerator, cremation incinerator designup to 6ton per day. Municipal Solid Waste, etc.  4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation

Items/Model YD-30 YD-50 YD-100 YD-150
Burning Rate (kgs/Hour) 30 kgs/Hr. 50 kgs/Hr. 100 kgs/Hr. 150 kgs/Hr.
Feed Capacity (kgs) 60 kgs 150 kgs 200 kgs 300 kgs
Equipment Weight 2300 kgs 4000 kgs 4300 kgs 7000 kgs
Primary Chamber (Liters) 360 900 1200 1500
Secondary Chamber (Liters) 200 200 500 500
External Dimensions (cm) 145x90x175 200x160x230 220x180x360 240x170x380
Internal Dimensions (cm) 100x60x60 120x90x85 130x100x90 150x100x96
Oil Tank(Liters) 200 300 300 500
Door Opening (cm) 48 x 60 62 x 80 55 x 80 59 x 81
Chimney (M) 5 5 10 10
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Medical Incinerator


Basic Info.

Export Markets:Global

Additional Info.

Trademark:CLOVER

Product Description

Q: What is kind of waste can utilize in this equipment?  A: This gear for medical waste, pet animal, Municipal waste, dwell waste. Prohibit any explosive and radiation material, liquid waste and gas waste.  GB18484-2001. 

Q: Treatment capacity  A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not indicate any waste material. The animal/pet combustion speed around 2/3 of average capacity. 

Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, there are about 0.5-1 hours cooling time and time for feeding waste. Burning incenrator manufactuer, burning medical waste, burning waste chamber, buy a portable crematorium, buy a small incinerator, buy animal cremation systems, Real combustion time per day is about 16 hours. The lifetime of incinerator between 5-10 year according to use. 

Generally, we proposition little lab, little clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people each day. If there are 200 sickbed at the hospital, that's mean you need 1 incinerator capacity around 400kgs each day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator.  *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste. 

Q: Assembly and Testing  A: We provide all documents and incinerators simple to setup and operation. Client can send people come to our factory to find out installation and operation. Generally, We do not send engineer to local site if not request. The dispatch cost is extra according to order.  The second combustion chamber: 1000-1200 centi level. 

Q: Incinerator Control Mode  A: Default Control mode is common control case. PLC mode according to model and order. 

Q: Operation and maintenance costs  A: Operation cost according to fuel consumption rate and power/staff, etc. 

Annual around $500-$1000USD per year maintenance according model, use situation. 

One person can service 02 unit incinerators. The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and understand risk of medical waste to safeguard worker self with essential protection component. 

One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element. 

Q: The Residency time in secondary combustion chamber 
A: 02 sec.

Items/Model YD-10C YD-20C YD-30C YD-50C
Burning Rate (kgs/Hour) 10 kgs/Hr. 20 kgs/Hr. 30 kgs/Hr. 50 kgs/Hr.
Feed Capacity (kgs) 40 kgs 40 kgs 50 kgs 80 kgs
Equipment Weight 1200 kgs 1200 kgs 1800 kgs 2200 kgs
Primary Chamber (Liters) 200 200 250 400
Secondary Chamber (Liters) 140 140 140 140
External Dimensions (cm) 170x140x160 170x140x160 170x140x190 180x160x200
Internal Dimensions (cm) 55x55x65 55x55x65 55x55x85 70x70x85
Oil Tank(Liters) 50 100 100 150
Door Opening (cm) 38 x 48 38 x 48 38 x 48 45×55
Chimney (M) 5 5 5 5
Chimney Type Stainless Steel Stainless Steel Stainless Steel Stainless Steel
Secondary Chamber  YES YES YES YES
Mix-Combustion Chamber YES YES YES YES
Smoke Filter Chamber YES YES YES YES
Combustion Fuel Oil/Gas Oil/Gas Oil/Gas Oil/Gas
Residency Time 2.0 Sec. 2.0 Sec. 2.0 Sec. 2.0 Sec.
Temperature Monitoring YES YES YES YES

Clover's Social Media