Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Modern Incinerators
Product Description
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *according to sequence * High temperature, long lifetime of incinerator. * Free or minimal installation on site. * PLC Control Plane. *based on order * New Design for pet animal cremation company. * One year warranty on incinerator and parts in stock.
TS version PLC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for kinds of site, like hospital, diesel and gas incinerator 50 kg per hour, diesel burner room, gas burner chamber incinerator, diesel burners, diesel cremation machines, diesel crematorium, environmental department, animal cremation bureaus, etc.. CLOVER Incinerator provide updated models with double combustion chamber and smoke filter room with refractory lines, and the combustion chamber temperature up to 1200 deg C.
| Items/Model | TS50(PLC) |
| Picture | |
| Burn Rate | 50 kg/hour |
| Feed Capacity | 100kg |
| Control Mode | PLC |
| Combustion Chamber | 560L |
| Internal Dimensions | 100x80x70cm |
| Secondary Chamber | 280L |
| Smoke Filter Chamber | Yes |
| Feed Mode | Manual |
| Voltage | 220V |
| Power | 0.7Kw |
| Oil Consumption (kg/hour) | 12.1–24 |
| Gas Consumption (m3/hour) | 9.9–26.1 |
| Temperature Monitor | Yes |
| Temperature Protection | Yes |
| Oil Tank | 100L |
| Feed Door | 70x55cm |
| Chimney | 5Meter |
| Chimney Type | Stainless Steel |
| 1st. Chamber Temperature | 800degree–1000degree |
| 2nd. Chamber Temperature | 1000degree-1200degree |
| Residency Time | 2.0 Sec. |
| Gross Weight | 4500kg |
| External Dimensions | 230x130x155cm |
Medical Waste Incinerators
Basic Info.
Product Description
TS version PLC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for types of site, like hospital, environmental department, animal cremation agencies, etc.. Pet cremation incinerators, mobile cremation furnace, mobile medical waste incinerator manufacture companies in china, red bag waste incinerator, CLOVER Incinerator supply updated models with dual combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.
Nanjing Clover Medical Technology Co., Ltd.. Is a major waste incinerator manufacturer in China. We’re local manufacturer and one of the greatest exporter of China. Pyrolytic incinerator equipment technical is primary waste treatment all of the world, for Medical waste, Pet animal cremation and other Solid waste. The capacity from 10kgs/Hr. To 600kgs/Hr. , up to 10ton per day.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Solid Waste Processing
Basic Info.
Additional Info.
Product Description
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *according to order * High temperature, long life of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. *according to order * New Design for pet animal cremation business. * One year warranty on incinerator and components in stock.
Key Features:
* All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long life. * High temperature, long life of incinerator. * High burn rate, from batch load incinerator, batch load waste incinerator, batch loading incinerator, up to 10ton daily. * PLC Control Plane for Intelligent operation. * New Design for pet animal batch electricity load, best mobile incinerator design, big capacity incinerator, 10kgs to 600kgs a hour, cremation business. * One year warranty on incinerator and components in stock. *Detail Specificaton according to order.
| Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
| Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
| Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
| Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
| Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
| Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
| External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
| Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
| Oil Tank(Liters) | 50 | 100 | 100 | 150 |
| Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
| Chimney (M) | 5 | 5 | 5 | 5 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |
Smokeless Incinerator
Product Description
Principle of the Incinerator Gear is incineration/combustion/burn.
The main body is 1 combustion chamber (at least), Refractory line or firebrick, Insulation materials and the outer plate. Ignition element is outside oil or gas burner. The burner can be sloutherhouse waste incineration lt, small 20kg incinerator, small a animal crematory equipment prices, small animal crematorium manufacturers, running until waste burnout but for some waste such as vinyl, newspaper (sometime, mix coal with waste before feeding), they can combustion itself after Ignition. During combustion, burner includes a fan itself for Oxygen source and protect burner avoid heat damage from combustion chamber. And, there a outside fan blow air into combustion chamber. The Exhaust gas blow out after combustion.
Considering Environmental Protection requirements and principles, almost all incinerator have secondary combustion chamber (after-burn, post-combustion), even if third combustion chamber. The secondary burner burn the Exhaust gas from primary combustion chamber, this technology make sure adequate combustion, few black smoke and smell.
The upgraded incinerator technology concentrate on Exhaust gas treatment to remove Hazardous material and other purpose from incinerator, like heat recovery (waste to energy), save fuel cost, PLC Automation operation.
Incinerator Double Burner with 50 Kg/Hr Capacity
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can utilize within this equipment? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid waste and gas waste. GB18484-2001.
Q: Treatment capacity A: Average Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion speed around 2/3 of average power.
Clover incinerator use time daily to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The life of incinerator between 5-10 year according to use.
Generally, we proposition small lab, small clinic use capacity under 20 kgs per hour. When incinerator use in hospital, please compute the waste output capacity around 2kgs per people per day. Pet crematory equipment, small incinerator available, smart ash incinerator price, 20kgs per hour incinerator, animal cremation equipment costs, If there are 200 sickbed in the hospital, that's mean you need 1 incinerator capacity around 400kgs per day, change to power per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We supply all documents and incinerators simple to installation and operation. Customer can send people come to our factory to find out operation and installation. Generally, We do not send engineer to local site if not request. The dispatch cost is additional according to order. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control manner is common control instance. PLC mode according to model and order.
One person can service 02 device incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and understand risk of medical waste to protect worker self with necessary security element.
Q: Operation and maintenance costs
A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |