Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Hospital Waste Incinerator 200 Kgs Per Hour Capacity
Product Description
Clover provide medical waste incinerators, animal and pet cremators, other solid waste incinerators to over 30 countries. We have re-designed the incinerators lining configuration. We have also designed and installed our very own PLC computer system into incinerator capacity of burner for medical incinerator, catalogue of incenarator for pharmaceuticals waste, chesp incinerator, china hazardous waste, operation system. Clover know it is essential that build them better, keep it simple and offer a great service. We create quality products that give excellent payback on investment, our incinerators will be the most powerful and thermally efficient in the industry. The incinerator lines have small scale to large scaleup to 500kgs per hour. The combustion chamber use high strength material, expensive cost but much better quality than competitors. Incinerator operation system utilize PLC program control manner, give up the complex manual operation. This gear quality structural for kinds of website, like hospital, environmental department, animal cremation agencies, etc.. CLOVER Incinerator provide updated models with dual combustion chamber, mix combustion chamber and smoke filter room with refractory lines, and the combustion chamber temperature up to 1200 deg C.
| Items/Model | YD-200 | YD-300 | YD-500 | YD-600 |
| Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. |
| Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs |
| Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs |
| Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 |
| Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 |
| External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 |
| Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 |
| Oil Tank(Liters) | 300 | 500 | 500 | 500 |
| Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 |
| Chimney (M) | 10 | 10 | 14 | 14 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |
Incinerator Calculations for Bunker Capacity
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can utilize in this equipment? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste. GB18484-2001. The animal/pet combustion speed around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, you will find approximately 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is about 16 hours. The life of incinerator between 5-10 year based on use.
Generally, we proposal small laboratory, small clinic use capability under 20 kgs per hour. When incinerator use in hospital, please compute the waste output capacity around 2kgs per people each day. Medical waste furnace, animal waste incinerator manufacturer, domestic incinerator, incinerator installation demonstration, medical incinerator costs, in case there are 200 sickbed in the hospital, that's mean you need 1 incinerator capacity around 400kgs each day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Testing and Assembly A: We provide all documents and incinerators simple to setup and operation. Customer can send people come to our factory to find out operation and installation. Generally, we don’t send engineer to local site if not request. The dispatch cost is additional according to order. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control mode is common control instance. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according version, use situation.
One individual can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on operation user guider, and know risk of medical waste to safeguard worker self with necessary protection element.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items | Specification | ||||
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
| Main Product List | Double Combustion Chamber | ||||
| Smoke Filter Chamber | |||||
| PLC Mode Control Case | |||||
| Stainless Steel Chimney | |||||
| Italy oil/gas burner: 02 units | |||||
| Oil Tank (if oil fuel) | |||||
Waste Incinerator
Basic Info.
Product Description
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Nanjing Clover Medical Technology Co., Ltd..
100 Kgs Per Hr Medical Waste Incinerator
Product Description
Nanjing Clover Medical Technology Co., Ltd..
| Items/Model | YD-30 | YD-50 | YD-100 | YD-150 |
| Burning Rate (kgs/Hour) | 30 kgs/Hr. | 50 kgs/Hr. | 100 kgs/Hr. | 150 kgs/Hr. |
| Feed Capacity (kgs) | 60 kgs | 150 kgs | 200 kgs | 300 kgs |
| Equipment Weight | 2300 kgs | 4000 kgs | 4300 kgs | 7000 kgs |
| Primary Chamber (Liters) | 360 | 900 | 1200 | 1500 |
| Secondary Chamber (Liters) | 200 | 200 | 500 | 500 |
| External Dimensions (cm) | 145x90x175 | 200x160x230 | 220x180x360 | 240x170x380 |
| Internal Dimensions (cm) | 100x60x60 | 120x90x85 | 130x100x90 | 150x100x96 |
| Oil Tank(Liters) | 200 | 300 | 300 | 500 |
| Door Opening (cm) | 48 x 60 | 62 x 80 | 55 x 80 | 59 x 81 |
| Chimney (M) | 5 | 5 | 10 | 10 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |
YD incinerator is newest design for waste treatment, include medical waste, animal cremation and other solid waste. This gear quality structural for types of website, like hospital, hospital waste incinerators, hospital waste incinerators china, hous hol waste incinerator technology, how to apply for an incinerator licence in south africa, environmental department, animal cremation bureaus, etc.. CLOVER Incinerator supply updated models with double combustion chamber, mix combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.
Little Mobile Veterinary Incinerator 20 Kg Hour Burn Rate
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can utilize in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, dwell waste. Prohibit any explosive and radiation substance, liquid waste and gas waste. GB18484-2001. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, you will find about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is around 16 hours. The life of incinerator between 5-10 year based on use.
Generally, we proposition small laboratory, small clinic use capability under 20 kgs per hour. Mobile incinerator, small animal incinerator, small scale incinerators,, chinese incinerator manufacturers, clover incinerater, hospital waste incinerator, When incinerator use in hospital, please compute the waste output capacity around 2kgs per people per day. If there are 200 sickbed in the hospital, that's mean you need one incinerator capacity around 400kgs per day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We provide all documents and incinerators simple to installation and operation. Customer can send people come to our factory to learn operation and installation. Generally, We do not send engineer to local site or even ask. The dispatch cost is additional according to order. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control mode is common control instance. PLC mode according to order and model.
Q: Operation and maintenance costs A: Operation price based on fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according version, use situation.
One individual can service 02 device incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower based on performance user guider, and know risk of medical waste to safeguard worker self with essential protection element.
Q: The Residency time in secondary combustion chamber A: 02 sec.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items | Specification | ||||
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
| Main Product List | Double Combustion Chamber | ||||
| Smoke Filter Chamber | |||||
| PLC Mode Control Case | |||||
| Stainless Steel Chimney | |||||
| Italy oil/gas burner: 02 units | |||||
| Oil Tank (if oil fuel) | |||||