Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Waste Medical Incinerators
Product Description
Nanjing Clover Medical Technology Co., Ltd..
| Items/Model | TS50(PLC) |
| Picture | |
| Burn Rate | 50 kg/hour |
| Feed Capacity | 100kg |
| Control Mode | PLC |
| Combustion Chamber | 560L |
| Internal Dimensions | 100x80x70cm |
| Secondary Chamber | 280L |
| Smoke Filter Chamber | Yes |
| Feed Mode | Manual |
| Voltage | 220V |
| Power | 0.7Kw |
| Oil Consumption (kg/hour) | 12.1–24 |
| Gas Consumption (m3/hour) | 9.9–26.1 |
| Temperature Monitor | Yes |
| Temperature Protection | Yes |
| Oil Tank | 100L |
| Feed Door | 70x55cm |
| Chimney | 5Meter |
| Chimney Type | Stainless Steel |
| 1st. Chamber Temperature | 800 degree–1000degree |
| 2nd. Chamber Temperature | 1000degree-1200degree |
| Residency Time | 2.0 Sec. |
| Gross Weight | 4500kg |
| External Dimensions | 230x130x155cm |
TS version PLC incinerator is newest design for waste treatment, include medical waste, animal cremation and other solid waste. This gear quality structural for kinds of site, crematory burner, crematory equipment, crematory equipment manufacture, crematory filter, crematory in china, crematory incineratorincineration, crematory manufacturer china, like hospital, environmental division, animal cremation agencies, etc.. CLOVER Incinerator supply updated models with dual combustion chamber and smoke filter room with refractory lines, and the combustion chamber temperature up to 1200 deg C.
Incinerator Ts-10 PLC
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can utilize within this equipment? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation substance, liquid waste and gas waste. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between each feed/combustion time, you will find approximately 0.5-1 hours cooling time and time for feeding waste. Medical waste, medical waste incinerator china, pet incineration equipment, pet incinerator available, portable incinerator manufacturers, waste incinerator producers from china, Actual combustion time per day is about 16 hours. The lifetime of incinerator between 5-10 year according to use.
Generally, we proposal little laboratory, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please compute the waste output capacity around 2kgs per people each day. If there are 200 sickbed in the hospital, that's mean you need one incinerator capacity around 400kgs each day, change to capacity per hour is around 30-40 kgs per hour. According the operation time per day, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to compute Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We provide all documents and incinerators easy to setup and operation. Customer can send people come to our factory to find out installation and operation. Generally, we don’t send engineer to local site if not request. The dispatch cost is extra according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi degree. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control manner is common control case. PLC mode according to order and model.
One person can service 02 device incinerators. The staff should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and know risk of medical waste to safeguard worker self with necessary protection component.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Medical Waste Incinerator
Basic Info.
Product Description
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *according to order * High temperature, long life of incinerator. * Free or minimal installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. *according to order * New Design for pet animal cremation company. * One year warranty on incinerator and parts in stock.
Program Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation
TS version PLC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This gear quality structural for types of website, like hospital, diesel-fueled medical waste incinerator, dioxine emission control medical hospital incinerator, disposal of biological waste incinerator, do they make a portable creamation furnance for pets, environmental department, animal cremation agencies, etc.. CLOVER Incinerator provide updated models with dual combustion chamber and smoke filter room with refractory lines, and the combustion chamber temperature up to 1200 deg C.
| Items | Specification | ||||
| Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
| Main Product List | Double Combustion Chamber | ||||
| Smoke Filter Chamber | |||||
| PLC Mode Control Case | |||||
| Stainless Steel Chimney | |||||
| Italy oil/gas burner: 02 units | |||||
| Oil Tank (if oil fuel) | |||||
High Performance Small Incinerator Plant
Product Description
Pyrolytic incineration specialized is conventional waste treatment way for several years. All over the world, in most countries, people anti incinerator since the incinerator will produce a large Dioxin from the smoke. Dioxins can be released into the environment through forest fires, krakow incinerator project, kwai chung incineration plant, kyrgyzstan waste to energy, lab scale incinerator supplier, lab crematorium, lab icinerator manufacturer, backyard burning of trash, certain industrial activities, and residue from previous commercial burning of waste. Dioxins break down very slowly and previous releases of dioxins from both natural and man-made sources still exist in the environment. Anyhow, we have to remind that, this is big scale incineration pant, generally greater than 30 ton per day. This is a social issue, to examine and suggest ways in different angles from the general public, government, economic growth, environmental protection, technology development, etc.
YDC incinerator is latest design for waste treatment, include medical waste, animal cremation and other solid waste. This equipment quality structural for types of website, like hospital, environmental department, animal cremation agencies, etc.. CLOVER Incinerator supply updated models with double combustion chamber, mix combustion chamber and smoke filter chamber with refractory lines, and the combustion chamber temperature up to 1200 deg C.
| Items | Specification | |||
| YDC Model | YD-10C / YD-20C / YD-30C / YD-50C | |||
| Main Product List | Primary Combustion Chamber | |||
| Secondary Combustion Chamber | ||||
| Mix Combustion Chamber | ||||
| Smoke Filter Chamber | ||||
| Incinerator Common Control Case | ||||
| Stainless Steel Chimney | ||||
| Italy oil/gas burner: 02 units | ||||
| Oil Tank (if oil fuel) | ||||
Waste Incineration
Basic Info.
Product Description
| Items/Model | YD-10C | YD-20C | YD-30C | YD-50C |
| Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. |
| Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs |
| Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs |
| Picture | ||||
| Primary Chamber (Liters) | 200 | 200 | 250 | 400 |
| Secondary Chamber (Liters) | 140 | 140 | 140 | 140 |
| External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 |
| Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 |
| Oil Tank(Liters) | 50 | 100 | 100 | 150 |
| Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 |
| Chimney (M) | 5 | 5 | 5 | 5 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |