Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Diesel and Gas Incinerator 50 Kg Per Hour
									
Basic Info.
Product Description
Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As different circumscription, incinerator can be termed many words as below:
Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Pyrolytic incineration technical is traditional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will create a large Dioxin in the smoke. “Dioxins” refers to a group of poisonous chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released to the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from previous commercial burning of waste. Dioxins break down very slowly and previous releases of dioxins from both natural and man-made sources still exist in the environment. Anyhow, we must remind that, this is large scale incineration pant, generally more than 30 ton per day. This is a societal problem, to analyze and suggest ways in different angles from the general public, government, economic development, environmental protection, technology development, etc.
So, why we use incinerator? First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management. Secondly, for individual body, pet animal, in many countries and areas, we desire to cremation them. This is the service in the process of society development, and ceremonies to commemorate the disappearance of life.
As above two reason but not just above, we still use incinerators.
How you can discover reasonable incinerator for your neighborhood site? Incinerator is not a cheap equipment, generally the small scale model's cost around $5, 000USD per unit and large scale model's cost more than $50, 000USD per unit. Animal incinerator 50kg, animal incinerator bidding, animal incinerator design, animal incinerator producers, animal incinerators in china, animal incinerators costs, So, before buy one unit incinerator, you have to make clear following items: A, burn what? Incinerator is a incineration equipment, function is flame waste. So what sort of waste you would like to treatment? B, small or large? This according to the waste output daily or the waste volume per feed time, like creature size. C, fuel? Incinerator use gas or oil fuel, generally, gas fuel is less expensive than oil and the smoke cleaner than oil fuel model. However, some local site don't have gas distribution system. And other technology items, like power(220V, 380V), waste feed door kind, incinerator structure, etc.
After you explain these, you can go to discover a local or worldwide manufacturers, asking prices, technical specifications and finally purchasing the ideal products.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) | 
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour | 
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg | 
| Control Mode | PLC | PLC | PLC | PLC | PLC | 
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L | 
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm | 
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L | 
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes | 
| Feed Mode | Manual | Manual | Manual | Manual | Manual | 
| Voltage | 220V | 220V | 220V | 220V | 220V | 
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw | 
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 | 
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 | 
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes | 
| Temperature Protection | Yes | Yes | Yes | Yes | Yes | 
| Oil Tank | 100L | 100L | 100L | 100L | 200L | 
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm | 
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg | 
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm | 
Build Secondary Combustion Incinerator Stove
									
Product Description
Nanjing Clover Medical Technology Co., Ltd..
Key Features: * All models with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *according to sequence * High temperature, long lifetime of incinerator. * Free or minimum installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. * PLC Control Plane. *based on order * New Design for pet animal cremation company. * One year warranty on incinerator and parts in stock.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) | 
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour | 
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg | 
| Control Mode | PLC | PLC | PLC | PLC | PLC | 
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L | 
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm | 
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L | 
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes | 
| Feed Mode | Manual | Manual | Manual | Manual | Manual | 
| Voltage | 220V | 220V | 220V | 220V | 220V | 
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw | 
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 | 
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 | 
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes | 
| Temperature Protection | Yes | Yes | Yes | Yes | Yes | 
| Oil Tank | 100L | 100L | 100L | 100L | 200L | 
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm | 
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg | 
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm | 
Application Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation Company License No.,: 320105000138343
Hospital Medical Waste Incinerator
									
Basic Info.
Product Description
Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be termed many words as below:
Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators Incinerator fuel: Gas incinerator, oil incinerator Waste to Energy (WTE): WTE incinerator, non-WTE incinerator Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. All around the world, in many countries, people anti incinerator since the incinerator will create a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from previous commercial burning of waste. Dioxins break down very slowly and previous releases of dioxins from both man-made and natural sources still exist in the environment. Anyhow, we have to remind that, this is large scale incineration pant, generally greater than 30 ton per day. This is a societal problem, fire brick incinerator, garden incinerators, gas chamber incinerator for animals, hazardous waste incinerator china, hazardous waste incinerators manufacturer, to examine and suggest ways in various angles from the public, government, economic growth, environmental protection, technology development, etc.
So, why we still use incinerator? First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management. Second, for human body, pet animal, in many countries and areas, we want to cremation them. This is the service in the practice of society development, and ceremonies to commemorate the disappearance of life.
As above two reason but not only above, we still use incinerators.
the way you can find reasonable incinerator for your neighborhood site? Incinerator is not a cheap equipment, generally the small scale version 's cost around $5, 000USD per unit and large scale version 's cost more than $50, 000USD per unit. So, before purchase one unit incinerator, you need to make clear following items: A, burn what? Incinerator is a incineration equipment, function is flame waste. So what kind of waste you would like to treatment? B, small or large? This according to the waste output daily or the waste quantity per feed period, like creature size. C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is less expensive than oil and the smoke cleaner than petroleum fuel model. However, some local site don't have gas supply system. And other technology products, like power(220V, 380V), waste feed door kind, incinerator construction, etc.
After you clarify these, you can go to find a local or worldwide manufacturers, asking prices, technical specifications and ultimately purchasing the right products.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) | 
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour | 
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg | 
| Control Mode | PLC | PLC | PLC | PLC | PLC | 
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L | 
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm | 
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L | 
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes | 
| Feed Mode | Manual | Manual | Manual | Manual | Manual | 
| Voltage | 220V | 220V | 220V | 220V | 220V | 
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw | 
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 | 
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 | 
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes | 
| Temperature Protection | Yes | Yes | Yes | Yes | Yes | 
| Oil Tank | 100L | 100L | 100L | 100L | 200L | 
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm | 
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg | 
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm | 
Large Scale Municipal Waste Incinerator
									
Product Description
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) | 
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour | 
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg | 
| Control Mode | PLC | PLC | PLC | PLC | PLC | 
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L | 
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm | 
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L | 
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes | 
| Feed Mode | Manual | Manual | Manual | Manual | Manual | 
| Voltage | 220V | 220V | 220V | 220V | 220V | 
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw | 
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 | 
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 | 
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes | 
| Temperature Protection | Yes | Yes | Yes | Yes | Yes | 
| Oil Tank | 100L | 100L | 100L | 100L | 200L | 
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm | 
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg | 
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm | 
Nanjing Clover Medical Technology Co., Ltd..
Small Waste Incinerator
									
Basic Info.
Product Description
Nanjing Clover Medical Technology Co., Ltd..
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator. * Free or minimal installation on site. * PLC Control Plane. *based on order * New Design for pet animal cremation company. * One year warranty on incinerator and components in stock.
| Items/Model | YD-10C | YD-20C | YD-30C | YD-50C | 
| Burning Rate (kgs/Hour) | 10 kgs/Hr. | 20 kgs/Hr. | 30 kgs/Hr. | 50 kgs/Hr. | 
| Feed Capacity (kgs) | 40 kgs | 40 kgs | 50 kgs | 80 kgs | 
| Equipment Weight | 1200 kgs | 1200 kgs | 1800 kgs | 2200 kgs | 
| Picture | ||||
| Primary Chamber (Liters) | 200 | 200 | 250 | 400 | 
| Secondary Chamber (Liters) | 140 | 140 | 140 | 140 | 
| External Dimensions (cm) | 170x140x160 | 170x140x160 | 170x140x190 | 180x160x200 | 
| Internal Dimensions (cm) | 55x55x65 | 55x55x65 | 55x55x85 | 70x70x85 | 
| Oil Tank(Liters) | 50 | 100 | 100 | 150 | 
| Door Opening (cm) | 38 x 48 | 38 x 48 | 38 x 48 | 45×55 | 
| Chimney (M) | 5 | 5 | 5 | 5 | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Secondary Chamber | YES | YES | YES | YES | 
| Mix-Combustion Chamber | YES | YES | YES | YES | 
| Smoke Filter Chamber | YES | YES | YES | YES | 
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Temperature Monitoring | YES | YES | YES | YES | 
Application Scope: 1. Hospital& practice: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation