Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Small Veterinary Incinerator 20 Kg Hour Burn Rate
Basic Info.
Product Description
Key Word: Little incinerators Medical waste incinerator Pet animal cremation incinerator Incinerator manufacturers
Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As distinct circumscription, incinerator can be termed many words as under:
Therapy capacity: Small scale incinerator, large scale incinerator and incineration pant. Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Pyrolytic incineration technical is traditional waste treatment way for many years. All around the world, in most countries, people anti incinerator since the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of poisonous chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both natural and man-made resources still exist in the environment. Medical incinerators 40 kgs capacity, medical incinerators china, medical incinerators manufacturer, medical solid waste incinerator 100kg, medical wast incinerator, Anyhow, we must remind that, this is big scale incineration pant, normally more than 30 ton each day. This is a societal issue, to examine and suggest ways in different angles from the general public, government, economic growth, environmental protection, technology development, etc.
So, why we use incinerator? Pyrolytic technology can kill the virus, contamination control. Second, for human body, pet animal, in most countries and areas, we want to cremation them. This is the service in the process of society development, and ceremonies to commemorate the disappearance of life.
As above two reason but not just above, we still use incinerators.
the way you can discover reasonable incinerator for your neighborhood website? Incinerator is not a cheap equipment, generally the small scale model's price around $5, 000USD per unit and large scale model's price more than $50, 000USD each unit. Thus, before purchase one unit incinerator, you need to make clear following things: A, burn what? Incinerator is a incineration equipment, function is flame waste. So what kind of waste you want to treatment? B, small or big? This according to the waste output daily or the waste quantity per feed period, like creature size. Incinerator use oil or gas fuel, generally, gas fuel is less expensive than oil and the smoke cleaner than petroleum fuel model. However, some local website don't have gas supply system. And other technology items, like power(220V, 380V), waste feed door type, incinerator structure, etc.
Once you describe these, you can go to discover a local or worldwide manufacturers, asking prices, technical specifications and ultimately purchasing the ideal products.
Wrote by Nicky
| Items/Model | YD-30 | YD-50 | YD-100 | YD-150 |
| Burning Rate (kgs/Hour) | 30 kgs/Hr. | 50 kgs/Hr. | 100 kgs/Hr. | 150 kgs/Hr. |
| Feed Capacity (kgs) | 60 kgs | 150 kgs | 200 kgs | 300 kgs |
| Equipment Weight | 2300 kgs | 4000 kgs | 4300 kgs | 7000 kgs |
| Primary Chamber (Liters) | 360 | 900 | 1200 | 1500 |
| Secondary Chamber (Liters) | 200 | 200 | 500 | 500 |
| External Dimensions (cm) | 145x90x175 | 200x160x230 | 220x180x360 | 240x170x380 |
| Internal Dimensions (cm) | 100x60x60 | 120x90x85 | 130x100x90 | 150x100x96 |
| Oil Tank(Liters) | 200 | 300 | 300 | 500 |
| Door Opening (cm) | 48 x 60 | 62 x 80 | 55 x 80 | 59 x 81 |
| Chimney (M) | 5 | 5 | 10 | 10 |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Secondary Chamber | YES | YES | YES | YES |
| Mix-Combustion Chamber | YES | YES | YES | YES |
| Smoke Filter Chamber | YES | YES | YES | YES |
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Temperature Monitoring | YES | YES | YES | YES |
Incinerator Combustion
Product Description
Key Word: Small incinerators Medical waste incinerator Pet animal cremation incinerator Incinerator manufacturers
Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be termed many words as under:
Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Pyrolytic incineration technical is conventional waste treatment way for many years. All over the world, in many countries, people anti incinerator because the incinerator will produce a large Dioxin from the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, 100kg capacity incinerator manufacturer in China, 10kg capacity incinerator, 10kgs per hour incinerator, 15 kg per hour incinerator cost, 150 kg puppy, 150kg. Web, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from both natural and man-made resources still exist in the environment. Anyhow, we have to remind this, that is big scale incineration pant, generally more than 30 ton each day. This is a social issue, to examine and suggest ways in different angles from the public, government, economic growth, environmental protection, technology development, etc.
So, why we still use incinerator? First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management. Secondly, for individual body, pet animal, in many countries and regions, we want to cremation them. This is the ceremony in the practice of society development, and ceremonies to commemorate the disappearance of life.
As above two reason but not only above, we still use incinerators.
the way you can find reasonable incinerator for your neighborhood website? Incinerator is not a cheap equipment, generally the small scale model's price around $5, 000USD per unit and large scale model's price more than $50, 000USD each unit. So, before buy one unit incinerator, you have to make clear following items: A, burn what? Incinerator is a incineration equipment, function is flame waste. So what sort of waste you want to treatment? B, small or big? This according to the waste output daily or the waste quantity per feed period, like animal size. C, fuel? Incinerator use oil or gas fuel, generally, gas fuel is less expensive than oil and the smoke cleaner than oil fuel model. But some local website don't have gas supply system. And other technology items, like power(220V, 380V), waste feed door type, incinerator structure, etc.
After you clarify these, you can go to find a local or international manufacturers, asking prices, technical specifications and finally purchasing the ideal products.
Wrote by Nicky
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Procedure Fire Brick Installation at Incinerator Oil and Gas
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can use in this equipment? A: This equipment for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation material, liquid waste and gas waste. GB18484-2001. The animal/pet combustion rate around 2/3 of average power.
Clover incinerator use time daily to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time and time for feeding waste. Actual combustion time per day is about 16 hours. The lifetime of incinerator between 5-10 year according to use.
Generally, we proposition little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed at the hospital, that's mean you need 1 incinerator capacity around 400kgs per day, change to power per hour is approximately 30-40 kgs per hour. Incinerator medical for practice, incinerator medical waste, incinerator information, incinerator of china manufature, incinerator pharma manufacturer waste, incinerator mobile suppliers from china, According the operation time per day, waste material, budget, development, etc, you may use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Testing and Assembly A: We provide all documents and incinerators simple to setup and operation. Customer can send people come to our factory to learn operation and installation. Generally, We do not send engineer to local site if not ask. The dispatch cost is extra according to order.
Q: Combustion Temperature A: The first combustion chamber: 800-1000 centi level. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control manner is common control case. PLC mode according to model and order.
One individual can service 02 device incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and understand risk of medical waste to protect employee self with necessary security element.
Q: Operation and maintenance costs
A: Operation cost according to fuel consumption rate and power/staff, etc.
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Incinerator for Pharmacuticals Comapny
Product Description
Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As distinct circumscription, incinerator can be named many words as under:
Therapy capacity: Small scale incinerator, large scale incinerator and incineration pant. Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Pyrolytic incineration technical is traditional waste treatment way for several years. All over the world, in many states, people anti incinerator because the incinerator will produce a large Dioxin from the smoke. “Dioxins” refers to a group of poisonous chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from previous commercial burning of waste. Dioxins break down very slowly and previous releases of dioxins from both natural and man-made resources still exist in the environment. Anyhow, we have to remind this, that is large scale incineration pant, generally greater than 30 ton each day. This is a societal problem, clover incineraters, clover medical China, clover medical net, clover-medical, clovermedical. Web, construction of an incinerator, price for incineration for pets cost of running 100kg, Cremation equipment price creature, to examine and suggest ways in various angles from the public, government, economic development, environmental protection, technology development, etc.
So, why we use incinerator? First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management. Secondly, for individual body, pet animal, in several states and regions, we desire to cremation them. This is the ceremony in the practice of society development, and ceremonies to commemorate the disappearance of existence.
As above two reason but not only above, we still use incinerators.
How you can discover reasonable incinerator for your neighborhood site? Incinerator is not a cheap equipment, generally the small scale model's price around $5, 000USD per unit and large scale model's price more than $50, 000USD each unit. Thus, before buy one unit incinerator, you have to make clear following items: A, burn what? Incinerator is a incineration equipment, function is flame waste. So what sort of waste you would like to treatment? B, small or large? This according to the waste output daily or the waste quantity per feed period, like creature size. C, fuel? Incinerator use gas or oil fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local site don't have gas supply system. And other technology products, like electricity (220V, 380V), waste feed door kind, incinerator construction, etc..
After you clarify these, you can go to discover a local or worldwide manufacturers, asking prices, technical specifications and finally purchasing the right products.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Oil Waste Incinerator
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What is kind of waste can use in this equipment? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any explosive and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001.
Q: Treatment capacity A: Typical Capacity calculated by medical waste(lower calorific power (L. C. P): 3.0TH Kcal/Kg per hour), not mean any waste material. The animal/pet combustion rate around 2/3 of average power.
Clover incinerator use time daily to 24 hours. Between each feed/combustion time, there are approximately 0.5-1 hours cooling time and time for feeding waste. Incinerator combustion chamber photograph, incinerator crematory, incinerator traders, incinerator gas fired, incinerator for medical waste, incinerator for medicial waste, Actual combustion time daily is about 16 hours. The life of incinerator between 5-10 year according to use.
Generally, we proposal small laboratory, small clinic use capability under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people per day. If there are 200 sickbed at the hospital, that's mean you need one incinerator capacity around 400kgs per day, change to power per hour is approximately 30-40 kgs per hour. According the operation time daily, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Assembly and Testing A: We provide all documents and incinerators simple to installation and operation. Customer can send people come to our factory to learn installation and operation. Generally, we don’t send engineer to local site or even ask. The dispatch cost is additional according to order. The second combustion chamber: 1000-1200 centi level.
Q: Incinerator Control Mode A: Default Control mode is common control instance. PLC mode according to model and order.
One person can service 02 unit incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and understand risk of medical waste to safeguard worker self with essential protection component.
Q: The Residency time in secondary combustion chamber A: 02 sec.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
Q: The Residency time in secondary combustion chamber
A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |