Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Hospital Incinerator
									
Basic Info.
Product Description
Waste Incinerator International Market Analytics Date.
Key Word: Small incinerators Medical waste incinerator Pet animal cremation incinerator Incinerator manufacturers
Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As distinct circumscription, incinerator can be named many words as under:
Treatment capacity: Small scale incinerator, large scale incinerator and incineration pant. Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators Incinerator fuel: Gas incinerator, oil incinerator Waste to Energy (WTE): WTE incinerator, non-WTE incinerator Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Pyrolytic incineration technical is conventional waste treatment way for several years. All around the world, in many countries, people anti incinerator since the incinerator will create a large Dioxin from the smoke. “Dioxins” refers to a group of poisonous chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from the natural and man-made sources still exist in the environment. Anyhow, we have to remind this, that is large scale incineration pant, generally more than 30 ton per day. This is a societal issue, to analyze and suggest ways in different angles from the public, government, economic development, environmental protection, technology development, etc.
So, why we use incinerator? Pyrolytic technology can kill the virus, pollution management. Second, for individual body, pet animal, in many countries and areas, we desire to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of life.
As above two reason but not only above, we still use incinerators.
How you can find reasonable incinerator for your local website? Incinerator is not a cheap equipment, generally the small scale version 's price around $5, 000USD per unit and large scale version 's price more than $50, 000USD per unit. So, before buy one unit incinerator, you need to make clear following things: A, burn what? Incinerator is a incineration equipment, function is fire waste. So what sort of waste you would like to treatment? B, small or large? Combustion equipment animal cremation furnace, 'concrete combustion incinerator',” clover incinerator” who,”animal crematorium equipment”,”biomedical waste” gasifier certificate,”china solid waste net”, This according to the waste output daily or the waste quantity per feed period, like animal size. C, fuel? Incinerator use gas or oil fuel, generally, gas fuel is less expensive than petroleum and the smoke cleaner than petroleum fuel model. However, some local website don't have gas supply system. And other technology products, like electricity (220V, 380V), waste feed door kind, incinerator structure, etc.
Once you describe these, you can go to find a local or international producers, asking prices, technical specifications and ultimately purchasing the right products.
| Items/Model | YD-30 | YD-50 | YD-100 | YD-150 | Items/Model | YD-200 | YD-300 | YD-500 | YD-600 | Items/Model | YD-200 | YD-300 | YD-500 | YD-600 | 
| Burning Rate (kgs/Hour) | 30 kgs/Hr. | 50 kgs/Hr. | 100 kgs/Hr. | 150 kgs/Hr. | Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. | Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. | 
| Feed Capacity (kgs) | 60 kgs | 150 kgs | 200 kgs | 300 kgs | Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs | Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs | 
| Equipment Weight | 2300 kgs | 4000 kgs | 4300 kgs | 7000 kgs | Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs | Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs | 
| Primary Chamber (Liters) | 360 | 900 | 1200 | 1500 | Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 | Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 | 
| Secondary Chamber (Liters) | 200 | 200 | 500 | 500 | Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 | Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 | 
| External Dimensions (cm) | 145x90x175 | 200x160x230 | 220x180x360 | 240x170x380 | External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 | External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 | 
| Internal Dimensions (cm) | 100x60x60 | 120x90x85 | 130x100x90 | 150x100x96 | Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 | Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 | 
| Oil Tank(Liters) | 200 | 300 | 300 | 500 | Oil Tank(Liters) | 300 | 500 | 500 | 500 | Oil Tank(Liters) | 300 | 500 | 500 | 500 | 
| Door Opening (cm) | 48 x 60 | 62 x 80 | 55 x 80 | 59 x 81 | Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 | Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 | 
| Chimney (M) | 5 | 5 | 10 | 10 | Chimney (M) | 10 | 10 | 14 | 14 | Chimney (M) | 10 | 10 | 14 | 14 | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Secondary Chamber | YES | YES | YES | YES | Secondary Chamber | YES | YES | YES | YES | Secondary Chamber | YES | YES | YES | YES | 
| Mix-Combustion Chamber | YES | YES | YES | YES | Mix-Combustion Chamber | YES | YES | YES | YES | Mix-Combustion Chamber | YES | YES | YES | YES | 
| Smoke Filter Chamber | YES | YES | YES | YES | Smoke Filter Chamber | YES | YES | YES | YES | Smoke Filter Chamber | YES | YES | YES | YES | 
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Temperature Monitoring | YES | YES | YES | YES | Temperature Monitoring | YES | YES | YES | 
Large Scale Municipal Waste Incinerator
									
Product Description
Waste Incinerator International Market Analytics Date.
Key Word: Little incinerators Medical waste incinerator Pet animal cremation incinerator Incinerator manufacturers
Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As different circumscription, incinerator can be termed many words as under:
Therapy capacity: Small scale incinerator, large scale incinerator and incineration pant. Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators Incinerator fuel: Gas incinerator, oil incinerator Waste to Energy (WTE): WTE incinerator, non-WTE incinerator Incinerator Manufacturer: China incinerator maker, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) Burning Rate: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Pyrolytic incineration technical is conventional waste treatment way for many years. All around the world, in many countries, people anti incinerator since the incinerator will create a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from past commercial burning of waste. Dioxins break down very slowly and past releasesparts for incinerators, pet cremation burner, pet cremation burners, pet cremation equipment price, pet cremations equipment china, pet crematorium + manufacturer china, of dioxins from both natural and artificial resources still exist in the environment. Anyhow, we must remind that, this is big scale incineration pant, generally more than 30 ton per day. This is a societal issue, to analyze and suggest ways in various angles from the general public, government, economic development, environmental protection, technology development, etc.
So, why we still use incinerator? First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management. Second, for individual body, pet animal, in many countries and areas, we want to cremation them. This is the ceremony in the process of society development, and ceremonies to commemorate the disappearance of existence.
As above two reason but not just above, we nevertheless use incinerators.
the way you can find reasonable incinerator for your local site? Incinerator is not a cheap equipment, generally the small scale model's price around $5, 000USD per unit and large scale model's price more than $50, 000USD per unit. Thus, before buy one unit incinerator, you have to make clear following items: A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you want to treatment? B, small or big? This according to the waste output daily or the waste quantity per feed time, like animal size. Incinerator use oil or gas fuel, generally, gas fuel is less expensive than oil and the smoke cleaner than petroleum fuel model. However, some local site don't have gas supply system. And other technology items, like power(220V, 380V), waste feed door kind, incinerator structure, etc.
After you clarify these, you can go to find a local or worldwide manufacturers, asking prices, technical specifications and finally purchasing the right products.
| Items/Model | YD-30 | YD-50 | YD-100 | YD-150 | Items/Model | YD-200 | YD-300 | YD-500 | YD-600 | Items/Model | YD-200 | YD-300 | YD-500 | YD-600 | 
| Burning Rate (kgs/Hour) | 30 kgs/Hr. | 50 kgs/Hr. | 100 kgs/Hr. | 150 kgs/Hr. | Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. | Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. | 
| Feed Capacity (kgs) | 60 kgs | 150 kgs | 200 kgs | 300 kgs | Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs | Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs | 
| Equipment Weight | 2300 kgs | 4000 kgs | 4300 kgs | 7000 kgs | Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs | Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs | 
| Primary Chamber (Liters) | 360 | 900 | 1200 | 1500 | Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 | Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 | 
| Secondary Chamber (Liters) | 200 | 200 | 500 | 500 | Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 | Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 | 
| External Dimensions (cm) | 145x90x175 | 200x160x230 | 220x180x360 | 240x170x380 | External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 | External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 | 
| Internal Dimensions (cm) | 100x60x60 | 120x90x85 | 130x100x90 | 150x100x96 | Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 | Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 | 
| Oil Tank(Liters) | 200 | 300 | 300 | 500 | Oil Tank(Liters) | 300 | 500 | 500 | 500 | Oil Tank(Liters) | 300 | 500 | 500 | 500 | 
| Door Opening (cm) | 48 x 60 | 62 x 80 | 55 x 80 | 59 x 81 | Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 | Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 | 
| Chimney (M) | 5 | 5 | 10 | 10 | Chimney (M) | 10 | 10 | 14 | 14 | Chimney (M) | 10 | 10 | 14 | 14 | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Secondary Chamber | YES | YES | YES | YES | Secondary Chamber | YES | YES | YES | YES | Secondary Chamber | YES | YES | YES | YES | 
| Mix-Combustion Chamber | YES | YES | YES | YES | Mix-Combustion Chamber | YES | YES | YES | YES | Mix-Combustion Chamber | YES | YES | YES | YES | 
| Smoke Filter Chamber | YES | YES | YES | YES | Smoke Filter Chamber | YES | YES | YES | YES | Smoke Filter Chamber | YES | YES | YES | YES | 
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Temperature Monitoring | YES | YES | YES | YES | Temperature Monitoring | YES | YES | YES | YES | Temperature Monitoring | YES | YES | YES | YES | 
Large Scale Incinerators for Medical Waste Disposal
									
Basic Info.
Product Description
Technology Respond(FAQ)
Q: What’s kind of waste can use within this equipment? A: This gear for medical waste, pet animal, Municipal waste, live waste. Prohibit any volatile and radiation material, liquid waste and gas waste.
Q: Incinerator Smoke Standard A: China Government Standard: No. GB18484-2001. The animal/pet combustion rate around 2/3 of average capacity.
Clover incinerator use time per day up to 24 hours. Between every feed/combustion time, you will find about 0.5-1 hours cooling time and time for feeding waste. Incineration china, incineration for animal producer, incineration in china, incineration of animal waste, incineration sterilization, incinerator 100 kg, incinerator 150 kg, Actual combustion time daily is around 16 hours. The life of incinerator between 5-10 year according to use.
Generally, we proposition little lab, little clinic use capability under 20 kgs per hour. When incinerator use in hospital, please calculate the waste output capacity around 2kgs per people each day. If there are 200 sickbed at the hospital, that's mean you need 1 incinerator capacity around 400kgs each day, change to capacity per hour is approximately 30-40 kgs per hour. According the operation time daily, waste material, budget, development, etc, you can use capacity from 30-50 kgs per hour incinerator. *How to calculate Animal Cremation Burn Rate: 2/3 of the medical waste.
Q: Testing and Assembly A: We provide all documents and incinerators simple to setup and operation. Client can send people come to our factory to learn operation and installation. Generally, we don’t send engineer to local site or even request. The dispatch cost is extra according to order. The second combustion chamber: 1000-1200 centi degree.
Q: Incinerator Control Mode A: Default Control mode is common control instance. PLC mode according to model and order.
One individual can service 02 device incinerators. The team should have basic electrician understanding to operate/inspect/maintaince incinerator/burner/blower according to performance user guider, and understand risk of medical waste to safeguard worker self with essential protection element.
 Q: Operation and maintenance costs 
 A: Operation cost according to fuel consumption rate and power/staff, etc. 
Annual around $500-$1000USD per year maintenance according model, use situation.
One person can service 02 unit incinerators. The staff should have basic electrician knowledge to operate/inspect/maintaince incinerator/burner/blower according to operation user guider, and know risk of medical waste to protect worker self with necessary protection element.
 Q: The Residency time in secondary combustion chamber 
 A: 02 sec.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) | 
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour | 
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg | 
| Control Mode | PLC | PLC | PLC | PLC | PLC | 
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L | 
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm | 
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L | 
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes | 
| Feed Mode | Manual | Manual | Manual | Manual | Manual | 
| Voltage | 220V | 220V | 220V | 220V | 220V | 
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw | 
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 | 
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 | 
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes | 
| Temperature Protection | Yes | Yes | Yes | Yes | Yes | 
| Oil Tank | 100L | 100L | 100L | 100L | 200L | 
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm | 
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg | 
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm | 
Medical Waste Incinerator
									
Product Description
Key Word: Small incinerators Medical waste incinerator Pet animal cremation incinerator Incinerator manufacturers
Incinerator is a incineration equipment, direct fire waste by gasoline fuel or oi fuel. As distinct circumscription, incinerator can be termed many words as under:
Therapy capacity: Small scale incinerator, large scale incinerator and incineration pant. Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators Incinerator fuel: Gas incinerator, oil incinerator Waste to Energy (WTE): WTE incinerator, non-WTE incinerator Incinerator Manufacturer: China incinerator maker, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. Famous Incinerator manufacturer firm: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Pyrolytic incineration technical is conventional waste treatment way for many years. All over the world, in most countries, people anti incinerator because the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of poisonous chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released into the environment through forest fires, backyard burning of trash, certain industrial activities, and residue from previous commercial burning of waste. Dioxins break down very slowly and previous releases of dioxins from the natural and man-made resources still exist in the environment. Anyhow, we have to remind that, this is big scale incineration pant, generally greater than 30 ton per day. This is a societal problem, to examine and suggest ways in various angles from the public, government, economic growth, environmental protection, technology development, etc.
So, why we use incinerator? Pyrolytic technology can kill the virus, pollution management. Second, for individual body, pet animal, in most countries and regions, we desire to cremation them. This is the service in the process of society development, and ceremonies to commemorate the disappearance of life.
As above two reason but not only above, we still use incinerators.
How you can find reasonable incinerator for your local site? Incinerator is not a cheap equipment, generally the small scale model's cost around $5, 000USD per unit and large scale model's cost more than $50, 000USD per unit. So, before purchase one unit incinerator, little incinerator for medical waste china, little incinerator medical waste maker, small incinerators medical, little natural gas garbage incinerators, small scale incinerator china, you have to make clear following items: A, burn what? Incinerator is a incineration equipment, function is fire waste. So what kind of waste you would like to treatment? B, small or big? This according to the waste output every day or the waste quantity per feed period, like creature size. C, fuel? Incinerator use gas or oil fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than petroleum fuel model. But some local site don't have gas supply system. And other technology items, like electricity (220V, 380V), waste feed door type, incinerator construction, etc.
After you clarify these, you can go to find a local or worldwide manufacturers, asking prices, technical specifications and finally purchasing the ideal products.
Wrote by Nicky
| Items/Model | YD-30 | YD-50 | YD-100 | YD-150 | Items/Model | YD-200 | YD-300 | YD-500 | YD-600 | Items/Model | YD-200 | YD-300 | YD-500 | YD-600 | 
| Burning Rate (kgs/Hour) | 30 kgs/Hr. | 50 kgs/Hr. | 100 kgs/Hr. | 150 kgs/Hr. | Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. | Burning Rate (kgs/Hour) | 200 kgs/Hr. | 300 kgs/Hr. | 500 kgs/Hr. | 600 kgs/Hr. | 
| Feed Capacity (kgs) | 60 kgs | 150 kgs | 200 kgs | 300 kgs | Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs | Feed Capacity (kgs) | 400 kgs | 500 kgs | 800 kgs | 1100 kgs | 
| Equipment Weight | 2300 kgs | 4000 kgs | 4300 kgs | 7000 kgs | Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs | Equipment Weight | 7600 kgs | 8300 kgs | 13000 kgs | 16500 kgs | 
| Primary Chamber (Liters) | 360 | 900 | 1200 | 1500 | Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 | Primary Chamber (Liters) | 2000 | 2400 | 4000 | 5500 | 
| Secondary Chamber (Liters) | 200 | 200 | 500 | 500 | Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 | Secondary Chamber (Liters) | 500 | 1200 | 1500 | 1500 | 
| External Dimensions (cm) | 145x90x175 | 200x160x230 | 220x180x360 | 240x170x380 | External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 | External Dimensions (cm) | 270 x 185 x 380 | 260x220x420 | 320x220x460 | 360 x 220 x 475 | 
| Internal Dimensions (cm) | 100x60x60 | 120x90x85 | 130x100x90 | 150x100x96 | Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 | Internal Dimensions (cm) | 180 x 115 x 96 | 220x110x100 | 257x147x108 | 300 x 147 x 125 | 
| Oil Tank(Liters) | 200 | 300 | 300 | 500 | Oil Tank(Liters) | 300 | 500 | 500 | 500 | Oil Tank(Liters) | 300 | 500 | 500 | 500 | 
| Door Opening (cm) | 48 x 60 | 62 x 80 | 55 x 80 | 59 x 81 | Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 | Door Opening (cm) | 59 x 81 | 90 x 110 | 108 x 128 | 108 x 128 | 
| Chimney (M) | 5 | 5 | 10 | 10 | Chimney (M) | 10 | 10 | 14 | 14 | Chimney (M) | 10 | 10 | 14 | 14 | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Secondary Chamber | YES | YES | YES | YES | Secondary Chamber | YES | YES | YES | YES | Secondary Chamber | YES | YES | YES | YES | 
| Mix-Combustion Chamber | YES | YES | YES | YES | Mix-Combustion Chamber | YES | YES | YES | YES | Mix-Combustion Chamber | YES | YES | YES | YES | 
| Smoke Filter Chamber | YES | YES | YES | YES | Smoke Filter Chamber | YES | YES | YES | YES | Smoke Filter Chamber | YES | YES | YES | YES | 
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Temperature Monitoring | YES | YES | YES | YES | Temperature Monitoring | YES | YES | YES | 
Crematorium Animal Equipment Diesel
									
Basic Info.
Product Description
Waste Incinerator International Market Analytics Date.
Key Word: Small incinerators Medical waste incinerator Pet animal cremation incinerator Incinerator manufacturers
Incinerator is a incineration equipment, direct fire waste by gas fuel or oi fuel. As distinct circumscription, incinerator can be named many words as below:
Therapy capacity: Small scale incinerator, large scale incinerator and incineration pant. Waste material: Municipal waste incinerator, medical waste incinerator, animal cremation incinerator, human cremators Incinerator fuel: Gas incinerator, oil incinerator Waste to Energy (WTE): WTE incinerator, non-WTE incinerator Incinerator Manufacturer: China incinerator manufacturer, UK incinerator manufacturer, USA incinerator manufacturer, India incinerator manufacturer. Famous Incinerator manufacturer company: Inciner8(UK), Clover Incinerator(China), Pennram (USA), Haat (India) Burning Speed: 5kgs/hour, 10 kgs/hour, 15 kgs/hour, 20 kgs/hour, 30 kgs/hour, 50 kgs/hour, 100 kgs/hour, 150 kgs/hour, 300 kgs/hour, 500 kgs/hour
Pyrolytic incineration technical is traditional waste treatment way for several years. All around the world, in most countries, people anti incinerator since the incinerator will produce a large Dioxin in the smoke. “Dioxins” refers to a group of toxic chemical compounds that share certain chemical structures and biological characteristics. Dioxins can be released to the environment through forest fires, backyard burning of trash, certain industrial activities, little waste incinerator, little waste incinerator manufacturers, small-scale medical incinerator, small-scale medical incinerators, tiniest incinerator, and residue from past commercial burning of waste. Dioxins break down very slowly and past releases of dioxins from the natural and man-made resources still exist in the environment. Anyhow, we must remind that, this is large scale incineration pant, generally greater than 30 ton per day. This is a societal problem, to analyze and suggest ways in different angles from the general public, government, economic growth, environmental protection, technology development, etc.
So, why we use incinerator? First, for the medical waste from hospital, the pyrolytic incinerators is best treatment up to now. Pyrolytic technology can kill the virus, pollution management. Second, for human body, pet animal, in most countries and regions, we desire to cremation them. This is the service in the practice of society development, and ceremonies to commemorate the disappearance of life.
As above two reason but not only above, we nevertheless use incinerators.
the way you can find reasonable incinerator for your neighborhood website? Incinerator is not a cheap equipment, generally the small scale version 's cost around $5, 000USD per unit and large scale version 's cost more than $50, 000USD per unit. Thus, before buy one unit incinerator, you have to make clear following things: A, burn what? Incinerator is a incineration equipment, function is flame waste. So what sort of waste you would like to treatment? B, small or large? This according to the waste output every day or the waste volume per feed period, like animal size. Incinerator use oil or gas fuel, generally, gas fuel is cheaper than oil and the smoke cleaner than oil fuel model. But some local website don't have gas distribution system. And other technology products, like power(220V, 380V), waste feed door type, incinerator structure, etc.
Once you clarify these, you can go to find a local or worldwide producers, asking prices, technical specifications and finally purchasing the right products.
| Items/Model | YD-30 | YD-50 | YD-100 | YD-150 | 
| Burning Rate (kgs/Hour) | 30 kgs/Hr. | 50 kgs/Hr. | 100 kgs/Hr. | 150 kgs/Hr. | 
| Feed Capacity (kgs) | 60 kgs | 150 kgs | 200 kgs | 300 kgs | 
| Equipment Weight | 2300 kgs | 4000 kgs | 4300 kgs | 7000 kgs | 
| Primary Chamber (Liters) | 360 | 900 | 1200 | 1500 | 
| Secondary Chamber (Liters) | 200 | 200 | 500 | 500 | 
| External Dimensions (cm) | 145x90x175 | 200x160x230 | 220x180x360 | 240x170x380 | 
| Internal Dimensions (cm) | 100x60x60 | 120x90x85 | 130x100x90 | 150x100x96 | 
| Oil Tank(Liters) | 200 | 300 | 300 | 500 | 
| Door Opening (cm) | 48 x 60 | 62 x 80 | 55 x 80 | 59 x 81 | 
| Chimney (M) | 5 | 5 | 10 | 10 | 
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | 
| Secondary Chamber | YES | YES | YES | YES | 
| Mix-Combustion Chamber | YES | YES | YES | YES | 
| Smoke Filter Chamber | YES | YES | YES | YES | 
| Combustion Fuel | Oil/Gas | Oil/Gas | Oil/Gas | Oil/Gas | 
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 
| Temperature Monitoring | YES | YES | YES | YES | 