Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Clinical Waste Incinerators
Nanjing Clover Medical Modern Technology Co., Ltd. is a leading waste burner manufacturer in China. We are local supplier and also one of the greatest merchant of China.The manufacturing center workshop neighborhood in liuhe Economic Growth Zone, suburban area of Nanjing and company office regional in midtown location. Currently, burner line items marketplace cover former Soviet Union location, Africa countries, Asia nations as well as middle east location. From year 2010, we bargained with updated modern technology from Europe and America manufacturers and also develop participation partnership in the region of China market. Competitors in various different nations market, country discrimination and also fears of intellectual residential property legal rights activate failure.
Disposal of biohazard waste
#gallery -1
#gallery -1.
margin-left: 0;.
/ * see gallery_shortcode() in wp-includes/media. php */.
.
{
(adsbygoogle = window.adsbygoogle || []).push({});|}
We are local manufacturer and among the largest merchant of China. Pyrolytic burner devices technological is primary waste treatment all the planet, for Clinical waste, Family pet animal cremation and various other Strong waste. The capacity from 10kgs/Hr. to 500kgs/Hr. , up to 6ton daily. Presently, we provide different collection for regional client demands and layout updated burner with our top innovation. The updated design feature of our range of incinerators make them among the most inexpensive worldwide.
border: 2px solid #cfcfcf;.
#gallery -1. gallery-caption
(adsbygoogle = window.adsbygoogle || []).push({});
/ * see gallery_shortcode() in wp-includes/media. php */.
Containerized Mobile Incinerator
Containerized Mobile Incinerators Main Feature: — Dual Combustion Chamber — Dual Italy Burner –Burning Rate: 10-100kgs per hour –Combustion Chamber: 0.1M3-1.2M3 — Mobile Incinerator, Standard shipping containers, Easy to move/transport system — Free Setup, Pre-installed incinerator, Ideal for decks — Ultraviolet lamp sterilization inside Optional Function/Parts/Material/Burning Speed: — Stainless Steel Chimney — Dry Smoke Filter Chamber — Chimney Height Custom Made — Upgrade/Downgrade Burning Rate
BURNER SCREENING AND ALSO COMMISSIONING
these details shall be completely and also simply marked on the container on the.
( ii) 75mm (3″″) port socket screwed B-SP as well as pipeline in the higher end of the storage tank having an unloading device to avoid the rise in storage space tank strain over the design tension and anxiety. The air vent pipe shall be empty of bends as well as will have a constant increase while being as fast as problem-free.
iii) 1No. Oil ignition system
– – The choice of British need as well as likewise type of storage tank
The container will be mounted using a 25mm loss in the direction of the water drain-off touching element. The distribution outlet will be raised inside the container to stay clear of availability of water in the distribution line. The significant service provider will definitely develop container assistances and also bund wall surface regions to information illustrations generated by the sub-contractor. A valued drain away from one of the most cost effective part of the container will be provided complete with tail pipe and likewise a specification for tube pipeline connection.
E-5
1.1.8 TRANSFER HAND PUMP
A semi rotating hand pump will be offered filling the afternoon storage tank from the oil drum. It’ll be set up complete with all of the needed pipelines installations and apparatus.
1.1.9 DAILY SERVICE CONTAINER
A day-to-day storage tank of tiny capability 1,800 Litres will be positioned at 2.5 metre high level in the heater room. Storage tank is going to be made from 6mm thick pushed steel plates of 1220mm x 1220mm black mild steel sheet, complete with bolted cover and likewise adequate venting. The storage tank will definitely satisfy BS 799 part 5 1995 along with be supplied with a materials watch tube. The container will be lagged with 50mm thick fibre glass insulation of 0.4 W/m2 thermal conductivity as well as also finished with 20SWG galvanized sheets cladding.
The container will certainly be analyzed for any kind of sort of escapes of which if any sort of type of is determined will definitely be made great before the tank is painted on the surface with rust preventing paint.
1.1.10 AUXILLIARY TOOLS
All pipework made use of in the oil storage space systems will be to B.S. 1387 heavy grade. Joints shall be screwed, and also adequate unions should be offered to permit basic removing the gear.
A 25mm size fire shutoff of the quick activity bar ran dead weight type will be set up, in the oil blood circulation line. This will certainly be kept in the job opportunity by a mild scale steel cable linked to a fusible web link. The fusible link is going to be placed directly over the heater. The relaxing heater oil feed pipeline from the high degree day container will be heated by an electrical mapping tape efficiently twisted round the pipeline. The pipe shall then be guarded with 25mm thick fiber glass insulation as well as finished with scale 22swg galvanized steel sheet.
The distribution pipeline from the mass oil tank to the high degree day has actually been set up by others nonetheless the tenderer shall allow internet connection to the high level day container. The tenderer will also supply and also set up high ability filters across the supply pipe as well as the heater feed pipeline.
1.1.11 PIPE SUPPORTS
The array and kind of assistances will be kept to a minimum as well as their design will be such as to market review together with safe handling to match concrete stonework or timber. When developing aids to the upkeep of preferred pipeline loss as well as the restraining of pipeline movements to a longitudinal axial directions only,
Consideration will be utilized.
The sub-contractor shall provide as well as set up all steel work creating a part of pipeline assistance settings up as well as will certainly be in charge of making good any kind of kind of problems to service providers function connected with contractors function installment.
Pipe runs will certainly be secured by clips attached to pipeline hangers, wall surface dental braces or trapeze type maintains. ‘‘ U’ screws will certainly not be made use of for clips with no previous authorization of the Designer.
The sub-contractor will send his whole proposal for the pipeline supports to the Engineer for authorization prior to any sort of erection job begins.
1.1.12 ELECTRICAL WORKS
All circuitry between things, plant along with controls will be implemented by the tenderer. The tenderer shall provide enough advice to make certain that electric links are properly made to all products of tools as well as controls offered by him, all to the Work Manager’s/ Designer’s satisfaction.
E-6
1.1.13 BURNER SCREENING as well as COMMISSIONING
The tenderer will certainly check and also appoint the burner in the occurrence of the Engineer.The tenderer will certainly additionally provide adequate oil to last a minimum of 2 (2) hours. The tenderer shall commission the burner as well as test in the existence of the Designer and also validate the burner is working according to the specifications laid here-in as well as in the brochures together with guidebooks from the providers of that incinerator.The burner efficiency examination will be done in conformity to BS3316: part 4:1987. Need to any sort of issue be identified, it will definitely be corrected and the testing process replicated to the Job Supervisor’s satisfaction.
1.1.14 FIRE INSTRUCTIONS ALERT
Continue and also acquire as well as likewise place as listed below;
Print fire directions on the Perspex plate, 3mm close White Colour.
1.1.5 OIL STORAGE As Well As ALSO SUPPLY
Photo-electric cells
2 collections of operating as well as upkeep handbooks (both for the incinerator along with heaters) need to furthermore be offered. Including 2 collections of controller schematic depictions for all of the controllers and also circuitry.
1.1.7 MASS OIL STORAGE TANK
The bulk oil storage tank minimal capacity of 10,200 litres and also complying with BS 799 component 5: 1975 shall be put on 3 concrete cradles.
The works will include supply, distribution, putting together, erection, testing, commissioning and planning to function. The container is to be of bound light steel kind with a structure anxiety of 40KN/m2 as well as storage space temperature of 240 C. It is to be located beside the burner as well as central heating boiler house.
The container shall be around with dished end as well as be made of 6mm thick block modest steel plates based on BS 1966. Top premium galvanized materials won’t be used.Welded building components shall be sprayed.
E-4
The tank will certainly be pressure analyzed with a general mind of water or fitting, evaluated from the bottom of the container, as well as also equivalent to 1 1/2 times the amount of:
(I) The elevation of the container and likewise
Correctly adjusted stick (of dip tape) and get to ladder to the top of the storage tank.
The packaging pipe shall be expanded inside the container to within 150mm of storage tank foundation,.
– – Test anxiety.
( iii) 65mm size filling pipe up with tube combining link
Centre line close to the electrical outlet connection.
– – Gross capacity in litres.
{
(adsbygoogle = window.adsbygoogle || []).push({});|}
( v) 50mm size supply pipe
– – Manufacturer’s title of job mark.{
(adsbygoogle = window.adsbygoogle || []).push({});|}
– – Day of examination. – Optimum allowed working anxiety.
A flue smokeshaft, 15,000 mm extensive and also 560mm size will be assembled from steel sheet, complete with lagging, damper and likewise water defense cone. The smokeshaft will certainly be lined with castable grade diatomaceous concrete combined with high alumina concrete based on BS 4076: 1989.
The damper will surely manage the closing of the door to not less than 85%. The heap is to permit fresh air in the supply’s foundation to make certain that the flue gases are found at stagnate afterwards 4000 C which the discharge satisfies the British Clean Air Act, the National Setting Management Agency (NEMA) Act or several other significant acts.
1.1.4 POWER SUPPLY
The sub-contractor will certainly supply tools which appropriate for operating a 415V, 3 point, 50HZ or 240V, solitary phase, 50HZ electric power distribution.
1.1.5 OIL STORAGE AND ALSO LIKEWISE SUPPLY
The system will incorporate a mass oil storage tank, daily storage tank, move hand gas pump as well as also linked pipe task. Oil from the mass tank will be provided to a high level daily storage tank located in the heater area by use of a transfer hand pump as well as automated electric pump. A part from the heater spares explained right here below, the spares rates are not to be included generally wrap-up of prices regular yet is to be separate and are shown to be ordered later on if as well as even when it ends up being needed as well as functional to the customer. The heating system conserves whose prices are to be contained generally summary of expenses schedule (BQ) are:-
I) 1No. Develop of safety and security controls
The strain will be elevated slowly as well as steadily up until the specified examination stress is gotten to which pressure will be maintained for a period adequate time to permit a thorough examination to be made to make certain that the tank is audio enough as well as discloses no leakages or excessive distortion.
The storage container will then be cleaned on the surface area and also provided with rust preventing guide before utilizing 2No.
The storage tank will be provided with the following:-
(I) 450mm bolted examination covers with liquid and vapour limited joint made with a gasket of gasoline immune materials.|{
(adsbygoogle = window.adsbygoogle || []).push({});|}
– – Test anxiety.
Centre line close to the electrical outlet connection.
– – Gross capacity in litres.
– – Manufacturer’s title of job mark.
( iv) 50mm dimension assessing relationship with lockable cap.
( iii) 65mm size filling pipe up with tube combining link
– – Day of examination. – Optimum allowed working anxiety.{
(adsbygoogle = window.adsbygoogle || []).push({});|}
Correctly adjusted stick (of dip tape) and get to ladder to the top of the storage tank.
The packaging pipe shall be expanded inside the container to within 150mm of storage tank foundation,.
ii) 1No. Solenoid valve