Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Latest Product
-
Aeration gate valve(wind valve) for waste incinerators
-
Fire proof flange gasket for burner on waste incinerator
-
Incinerator Automatic Protection Operator(APO) Controller
-
Model TS100(PLC) Waste Incinerator with S.Steel Wet scrubber(spray tower)
-
Thermal Radiation/ High Temperature Apron Incinerator PPE
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Reliable Medical Waste Incinerators for Conflict Zones C HICLOVER Supports MSF in Iraq, Afghanistan, and Somalia
In regions affected by war, poverty, or limited infrastructure, effective and safe disposal of medical waste is critical to prevent the spread of disease and protect public health. Médecins Sans Frontières (MSF), also known as Doctors Without Borders, has been at the frontline of humanitarian aid in countries like Iraq, Afghanistan, and Somalia. In their operations, medical incinerators play a vital role―especially when reliable, high-temperature destruction of biohazardous waste is required in remote or high-risk locations.
One proven solution MSF has chosen is the HICLOVER Incinerator, particularly models like TS30 PLC and TS75 PLC. These compact yet powerful incinerators are specifically designed to meet the rigorous demands of humanitarian medical operations.
Why MSF Chooses HICLOVER Medical Incinerators
1. High-Temperature Combustion
HICLOVER incinerators ensure complete combustion above 1000°C, effectively destroying harmful pathogens and reducing waste to sterile ash. This is essential for hospital environments where biohazards, needles, and infectious materials are handled daily.
2. Reliable Operation in Harsh Conditions
From refugee camps in northern Iraq to remote clinics in Somalia, TS30 PLC and TS75 PLC incinerators operate reliably even in areas with unstable infrastructure. Their diesel or LPG-powered combustion systems allow them to function without relying on electric grids.
3. Compact & Mobile Design
These models feature a modular structure, making them easy to transport, install, and maintain on-site. For field hospitals and temporary MSF medical bases, this flexibility is crucial.
4. Safe and Compliant
With dual combustion chambers, PLC control systems, and flame-retardant linings rated up to 1750°C, these incinerators ensure safe emissions and meet international environmental safety standards.
Models in Use: TS30 PLC & TS75 PLC
-
TS30 PLC: Designed for smaller medical centers, this incinerator handles 15C30 kg/hour of medical waste. Ideal for mobile clinics and field hospitals.
-
TS75 PLC: With a 30C75 kg/hour incineration capacity, this model supports medium-sized hospitals and long-term humanitarian facilities.
Global Commitment to Clean Medical Waste Management
HICLOVER is proud to support international organizations like MSF in their life-saving missions. By delivering containerized, top-loading, and automatic incinerator systems, we enable medical professionals to focus on care―while ensuring environmental and public health safety.
Our incinerators have been deployed in over 80 countries, serving not only humanitarian NGOs but also UN camps, military bases, and national hospitals.
About HICLOVER
HICLOVER Environmental Protection Solutions specializes in the manufacture of industrial-grade waste incinerators for:
-
Medical waste
-
Hazardous solid waste
-
Animal carcass and pet cremation
-
Remote and mobile field units
We offer tailored systems featuring:
-
Italy-made Riello burners
-
Optional wet scrubber systems
-
PLC/automatic control
-
Multiple combustion chambers
Related Topics:
Choose HICLOVER. Choose Clean. Choose Safe.
If you are a healthcare provider, NGO, or government agency operating in regions with poor waste management infrastructure, partner with HICLOVER for reliable, compliant, and field-tested medical incineration solutions.
small scale incinerator
Manufacturer to provide necessary information for the best of the setup
The control panel shall have all appropriate audible and visual alarms to ensure safe performance.
This incinerator with”PYROLYTIC” combustion must have:
A timer with adjustable temporization for the regulation of every burner.
?
? Nature: Calcium
OA burner of lighting that the use is limited to the ignition of waste.
OComposition of the refractory;
Electric box
The secondary combustion chamber must destroy the contaminant merchandise and must resist to high temperature(1100 °C)
Process Filtering system: Scruber to be mentionned as optional
A room of post combustion of gases
OElectro-ventilator distributing the secondary air, the regulation of the air flow being carried out by valves and adhering to the control of the automatic cycle.
? Burner of light of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and security of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.
. Nature: 42 percent of Al203
A regulator with digital watching for the temperature of combustion.
OBurner with fuel, mono-bloc casting directing type with flat flame, lighting and security of electronic ignition, permanent venting, electromagnetic sluice gate of regulation and isolating valve.
OThe insulation of the combustion chamber ought to be composed of refractory bricks, having a high content of aluminum and insulates bricks in order to guarantee a minimum temperature on the exterior sheet metal.
? Nature: 65% of Al203
? Thickness: ≥85 mm
OCarcass in strong sheet steel with support of connection.
oA burner of combustion of gases,
Incinerators Biological waste disposal system (incinerator)
Incinerator must satisfy the following specifications:
– Combustion capacity (kW) = 581 +/-10%
– Combustion capacity (kcal/h) = 500,000 +/-10%
– Max. . 50% water content) = 100 +/-10%
Further specifications will be supplied with the inquiry.
The incinerator shall be fully self contained.
The incinerator plant shall incorporate a control panel for its own operation. On the control panel we shall have a visual display of the room temperatures. This visual display must control and monitor the incinerator along with his performance.
Ability of destruction in weight shall be 60 Kg/h.
It should be able to operate not less than 10 hours/day
This incinerator must have the ability to destruct all combustible wastes produced by hospitals, private practices, laboratories, institutes, etc…
Design Specification: Types A, B, C, D, and E of medical waste
“PYROLYTIC” combustion, by controlling the gasification of waste.
The incinerator must prevent the discharge of black smoke and fine dust, during the loadings.
It shall have the ability to decrease the quantity of wastes by 98%.
It shall have the ability to hold emission in the next burn with gas residence of less than two seconds.
The incineration should be wholly free from visible smoke as well as offensive odours.
1.0The primary ignition burner shall providing ignition of the waste to 850 °C and must switch off to conserve fuel.
the principal combustion chamber shall be constructed from heavy steel plate and the unit is internally lined with a comprehensive layer of hote face refractory and high efficiency insulation.
The Internal diameter of the Chimney at least: ? 400 and its height: 8 m
The loudness of the combustion chamber at least: 1.200 L
The Dimension of the door for loading in cm : 70×70.
Burner operation should be Automatic On/Off
? Insulate in fibrous panels :
OFrontage of loading door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.
OA secondary injection of air to ensure perfect oxygen content.
A control box ensuring the whole cycle of combustion.
1. A combustion chamber of waste:
. Thickness : ≥100 mm
o Composition of the refractory;
? Refractory concrete :
Controls and regulations:
?
Control box watertight into dust, such as:
A switch circuit breaker for each engine (ventilators and burners).
OPerfectly tight doorway for the manual loading of waste.
OA sheath of evacuation of the gases burnt.
A regulator with digital watching for the temperature of post combustion.
OA device of injection of air allowing a total recombustion of gases,
Process Filtering system: Scruber to be mentionned as optional
Scientific waste burner 100kgs Style TS100
incinerator manufacturer,medical incinerator,small scale incinerator,oil fired incinerator
{
(adsbygoogle = window.adsbygoogle || []).push({});|}
(adsbygoogle = window.adsbygoogle || []).push({});Items/Model
TS100
Reduce Price
Frequent 100 kg/hour
Feed Capacity
Standard 200 kg/feed
Control Mode
PLC
Combustion Chamber
1200L
Interior Measurements
120x100x100cm
Second Chamber
600L
Smoke Filter Chamber
Yes
Feed Mode
Manual
Voltage
220V
Power
0.7 Kw
Oil Intake (kg/hour)
14– – 28
Gas Consumption (m3/hour)
10– – 32.2
Temperature Level Monitor
Yes
Temperature Level Degree Protection
Yes
Oil Container
200L
Feed Door
80x60cm
Smokeshaft
10Meter
Smokeshaft Kind
Stainless-steel
1st.
Gross Weight
6000kg
External Dimensions
260x150x180cm
2020-04-06
External Measurements
260x150x180cm
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-04-06
HICLOVER Medical Facility Medical Waste Heater in Stock for 2019-nCoV SARS-CoV, sars, coronavirus, Unique coronavirus
| Model | Capacity/Burnning Rate | For Hospital SickBed No. | Fuel Type | Qty. | Ready for Shipping | New Production | Shipping Volume | Shipping Weight | Delivery Location |
| TS30 | average 30kgs per hour | Average 150 SickBed | Diesel Oil | 1 set | 5 days | 20sets/2 weeks | 5 m3 | 3000 kgs | Shanghai Port |
| TS50 | average 50kgs per hour | Average 250 SickBed | Diesel Oil | 1 set | 7 days | 20sets/2 weeks | 7m3 | 4500 kgs | Shanghai Port |
| TS100 | average 100kgs per hour | Average 500 SickBed | Diesel Oil | 1 set | 7 days | 15sets/2 weeks | 10m3 | 6000 kgs | Shanghai Port |
| TS150 | average 150kgs per hour | Average 750 SickBed | Diesel Oil | 5 sets | 7 days | 15sets/2 weeks | 13m3 | 7500 kgs | Shanghai Port |
| YD10 | average 10kgs per hour | Average 50 SickBed | Diesel Oil | 2sets | 7 days | 20sets/2 weeks | 3m3 | 1200 kgs | Shanghai Port |
| YD20C | average 20kgs per hour | Average 100 SickBed | Diesel Oil | 2sets | 7 days | 20sets/2 weeks | 6m3 | 2000 kgs | Shanghai Port |
| YD50C | average 50kgs per hour | Average 250 SickBed | Diesel Oil | 2sets | 7 days | 20sets/2 weeks | 7m3 | 2300 kgs | Shanghai Port |
| YD30 | average 30kgs per hour | Average 150 SickBed | Diesel Oil | 1 set | 5 days | 20sets/2 weeks | 5m3 | 2300 kgs | Shanghai Port |
| YD30 Small | average 30kgs per hour | Average 150 SickBed | Diesel Oil | 2sets | 5 days | 20sets/2 weeks | 3m3 | 1500 kgs | Shanghai Port |
| YD50 | average 50kgs per hour | Average 250 SickBed | Diesel Oil | 2 sets | 5 days | 20sets/2 weeks | 8m3 | 4500 kgs | Shanghai Port |
| YD100 | average 100kgs per hour | Average 500 SickBed | Diesel Oil | 1 set | 10 days | 15sets/2 weeks | 13m3 | 6000 kgs | Shanghai Port |
| YD150 | average 150kgs per hour | Average 750 SickBed | Diesel Oil | 1 set | 10 days | 15sets/2 weeks | 17m3 | 7500 kgs | Shanghai Port |
| YD300 | average 300kgs per hour | Average 1500 SickBed | Diesel Oil | 10sets/2 weeks | 20m3 | 9000 kgs | Shanghai Port | ||
| YD500 | average 500kgs per hour | Average 2500 SickBed | Diesel Oil | 5sets/2 weeks | 27m3 | 13000 kgs | Shanghai Port | ||
| CA 50 Mobile Containerized | average 50kgs per hour | Average 250 SickBed | Diesel Oil | 2 sets | 15 days | 10sets/2 weeks | 28m3 | 7000 kgs | Shanghai Port |
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-04-03
HICLOVER Medical Waste Burner in Supply( Finished as well as New and semi-finished Production).
| Model | Capacity/Burnning Rate | For Hospital SickBed No. | Fuel Type | Qty. | Ready for Shipping | New Production | Shipping Volume | Shipping Weight | Delivery Location |
| TS30 | average 30kgs per hour | Average 150 SickBed | Diesel Oil | 1 set | 5 days | 20sets/2 weeks | 5 m3 | 3000 kgs | Shanghai Port |
| TS50 | average 50kgs per hour | Average 250 SickBed | Diesel Oil | 1 set | 7 days | 20sets/2 weeks | 7m3 | 4500 kgs | Shanghai Port |
| TS100 | average 100kgs per hour | Average 500 SickBed | Diesel Oil | 1 set | 7 days | 15sets/2 weeks | 10m3 | 6000 kgs | Shanghai Port |
| TS150 | average 150kgs per hour | Average 750 SickBed | Diesel Oil | 5 sets | 7 days | 15sets/2 weeks | 13m3 | 7500 kgs | Shanghai Port |
| YD10 | average 10kgs per hour | Average 50 SickBed | Diesel Oil | 2sets | 7 days | 20sets/2 weeks | 3m3 | 1200 kgs | Shanghai Port |
| YD20C | average 20kgs per hour | Average 100 SickBed | Diesel Oil | 2sets | 7 days | 20sets/2 weeks | 6m3 | 2000 kgs | Shanghai Port |
| YD50C | average 50kgs per hour | Average 250 SickBed | Diesel Oil | 2sets | 7 days | 20sets/2 weeks | 7m3 | 2300 kgs | Shanghai Port |
| YD30 | average 30kgs per hour | Average 150 SickBed | Diesel Oil | 1 set | 5 days | 20sets/2 weeks | 5m3 | 2300 kgs | Shanghai Port |
| YD30 Small | average 30kgs per hour | Average 150 SickBed | Diesel Oil | 2sets | 5 days | 20sets/2 weeks | 3m3 | 1500 kgs | Shanghai Port |
| YD50 | average 50kgs per hour | Average 250 SickBed | Diesel Oil | 2 sets | 5 days | 20sets/2 weeks | 8m3 | 4500 kgs | Shanghai Port |
| YD100 | average 100kgs per hour | Average 500 SickBed | Diesel Oil | 1 set | 10 days | 15sets/2 weeks | 13m3 | 6000 kgs | Shanghai Port |
| YD150 | average 150kgs per hour | Average 750 SickBed | Diesel Oil | 1 set | 10 days | 15sets/2 weeks | 17m3 | 7500 kgs | Shanghai Port |
| YD300 | average 300kgs per hour | Average 1500 SickBed | Diesel Oil | 10sets/2 weeks | 20m3 | 9000 kgs | Shanghai Port | ||
| YD500 | average 500kgs per hour | Average 2500 SickBed | Diesel Oil | 5sets/2 weeks | 27m3 | 13000 kgs | Shanghai Port | ||
| CA 50 Mobile Containerized | average 50kgs per hour | Average 250 SickBed | Diesel Oil | 2 sets | 15 days | 10sets/2 weeks | 28m3 | 7000 kgs | Shanghai Port |
| 1. Information High frequency change, for reference only. | |||||||||
| 2. Price as formal quotation and technical details and business term |
Tel: +86-25-8461 0201
Website: www.hiclover.com
Email: [email protected]
Email: [email protected]
2020-03-29