Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Clover’s Social Websites
Controlled air medical waste incinerator designed for incineration of bio-medical waste
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required
Standards1) Bidder or Manufacturer ISO 9001 Certified2) Respecting international emission standardsElectrical characteristics3) A 230V, 60Hz single-phase electrical source.4) Protections against over-voltage and over-current line conditions.5) Compliance with applicable Ghanaian Criteria and regulations.Operational characteristics6) Two-stage incineration with Double chamber combustion7) Burn rate: 15 – 20 Kg/h8) Ability: less than 130 L9) Concentrations of most pollutants in stack gases under detection limits10) Diesel fuel11) Electronic system control12) Easy to operate and Nominal training13) Any Attachment or Committed Apparatus necessary to the proper Operation and Use of the equipment included
Supply of Inclinators for Interim Arrival Domestic Terminal Project
Design, Manufacture, Supply, delivery to site, installation, testing & commission of All weather proof Passenger Inclinators in accordance to the Scope and outline specifications mentioned in Annexure
Spesifikasi Incinerator 100kg/jam
Spesifikasi dan Daftar Material
Dimensi dan Power Capacity
Nama Barang: INCINERATORType / Model: PWR-INC-KMN 10Kapasitas: 100kg/Jam (1 m3)Length: 288 cm Width: 147 cm Height: 163 cm Height of Chimney std: 700 cm TOTAL WEIGHT: 8000 kg Panel — timer: Digital Included Auto AlarmFinishing: Hot endured paint Fuel tank: 200 Liter Covering Element from steel: 3-8mm Banyaknya Burner: 2 pcs Banyaknya Blower: 2 pcs Max. Gas consumption: 15-30 Liter/Jam Max. Elektric consumption: 1100 Watt Bahan bakar: Kerosene / Diesel (solar) Voltage: 220 V / 1 phase / 50 Hz
Substance
1. PANEL CONTROL
Type: Digital Buatan: Local KAMINE ( Panel dan Incinerator satu Merek)Voltage: 220 V / 1 phase / 50 Hz Safety operator: Emergency Stop System: Microkontroller Pengoperasian: Semi AutomaticTemperatur controller: Digital Coupler TypeControl panel: Manual dan automaticTipe: Self Standing Sort / Wall Mounted TypeMaterial: Mild steelThermocontrol: two (Dua) 1200 ºCSet of timer: 0- 2 jamTombol saklar: on/off
2. DIMENSION OF CHAMBER (Dimensi Ruang Bakar)
Chamber 1 Ruang Bakar Utama: 100 x 100 x 98 cm = 980.000 cm3 = 0.98 m3Chamber 2 Ruang Bakar Kedua: 40 x 100 x 98 cm = 392.000 cm3= 0.39 m3
4. INSTRUMENTATION & KONTROL 1. Power Supply (volt / fase / herts): 15A / 220 V / 1 Phase / 50 Hz 3. Panel kandang: Mild Steel + powder coating 4. Thermocouple: K – Jumlah: 2 (dua) unit – Bahan: Stainless Steel + Ceramic 5. Timer: 0-2 Jam 6. De-ashing: Manual 7. System pembuangan Abu 2 unit 6. PINTU Pintu: Baja ringan dan Linning dengan castable System: Dual lock system ( penguncian ganda )
7. AIR SUPPLY SYSTEM Model / Type: enthusiast sentrifugal 3 “Kapasitas (m3/minute): 3.000 m3/mntStatis Tekanan (mmAq): 98 mmAqPower: 200 watt/unitJumlah (unit): 2 (dua)
8. FUEL SYSTEM Pembakaran Burner:Sort: Gun kind OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower: 250 wattJumlah unit: 1 unit
Sort: Gun kind OM 2NBahan Bakar: Diesel Oil / KeroseneKonsumsi Bahan Bakar: 10-18 ltr / jamPower: 250 wattJumlah unit: 1 unit
9. THERMOCOPLERuang bakar pertama dan keduaTipe: KProtective tube: Stainless steel + ceramicMax. Temperature: 1200 ºCJumlah: two unitSistem pemberian umpan: ManualSistem pengeluaran hasil: Manual
10. TANGKI BAHAN BAKARMaterial: Mild steel Kapasitas: 200 liter
10. TANGKI BAHAN BAKAR
Material : Mild steel
Kapasitas : 200 liter
Sterilizing chamber: Steam-heated via double back wall with integrated steam generator
Door and lock: Hinged door with quick lock and safety lock
Door seal: Blow-out design, even closure, automatic return without vacuum system
Temperature measurement technology: 2 independent sensors for controlling the steam generator + 1 sensor for sterilizing chamber
Preheating key
Security key switch saves program settings
Sterilization phase indicators
Pressurized-air supply: integrated Compressor for door control circuit and pneumatic set valves
Feed water consumption per batch 0.7 to 5.6 liters
Cooling water consumption per batch for spent-steam condenser 10–25 l at temperatures 15 °C
Water-level control: Within the double back wall
Low-water safety fuse: Heater Over temperature monitor
Sterile venting: Membrane filter 0,2um, 0.1 m² hydrophobic, steam-sterillisable, retention 99.5%
Control circuits: separate for heater and door seal, process control and monitoring
Timer Program start by date and time
Selectable Acoustic alarm at program end
Transport security device for door
Three Autoclave able (Polypropylene or stainless steel) Pans 5-10L
Controlled air medical waste incinerator designed for incineration of bio-medical waste

Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required
Standards
1) Bidder or Manufacturer ISO 9001 Certified
2) Respecting international emission standards
Electrical characteristics
3) A 230V, 60Hz single-phase electrical source.
4) Protections against over-voltage and over-current line conditions.
5) Compliance with applicable Ghanaian standards and regulations.
Operational characteristics
6) Two-stage incineration with dual chamber combustion
7) Burn rate: 15 – 20 Kg/h
8) Capacity: not less than 130 L
9) Concentrations of most pollutants in stack gases below detection limits
10) Diesel fuel
11) Electronic system control
12) Easy to operate and minimal training
13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included
PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION
Combustion Chamber Volume (m3) 8.80m3
Burn Rate* up to 1,500kg per hour
Average Fuel Consumption 65 kg per hour or more (7 diesel burners)
Operational Temperature 850 – 1320°C
Gas Retention in Secondary Chamber Large secondary chamber
Temperature Monitoring Yes
Average ash residue (%) 3%
Thermostatic Device Yes
1000l diesel flue tank
Venture gas scrubber
Hydraulic Ram Feeding System
Diesel Powered Large Incinerator
Minimum Specification Required
Standards
1) Bidder or Manufacturer ISO 9001 Certified
2) Respecting international emission standards
Electrical characteristics
3) A 230V, 60Hz single-phase electrical source.
4) Protections against over-voltage and over-current line conditions.
5) Compliance with applicable Ghanaian standards and regulations.
Operational characteristics
6) Two-stage incineration with dual chamber combustion
7) Burn rate: 15 – 20 Kg/h
8) Capacity: not less than 130 L
9) Concentrations of most pollutants in stack gases below detection limits
10) Diesel fuel
11) Electronic system control
12) Easy to operate and minimal training
13) Any accessory or dedicated device necessary to the proper functioning and utilization of the equipment included
PLEASE REFER TO BROCHURES ATTACHED FOR DETAILED SPECIFICATION