Doubel Combustion Chamber
All Incinerators are Doubel Combustion Chamber with One Fuel Burner Each. After Burner Technology for Completely Combustion and Cleaner World.
Read MoreHigh Temperature Incineration
Temperature Range 800 Degree to 1200 Degree in Combustion Chamber. Temperature Thermocouple Monitor and Controller. High Quality Fire Brick and Refactory Cement.
Read MoreGet Lastest News
There are latest incinerator news like technical, public news, business tender for medical waste incinerator,animal incineration, pet cremation
Read MoreNanjing Clover Medical Technology Co.,Ltd.
Email: sales@clover-incinerator.com | Tel: +86-25-8461 0201
Regular model incinerator for market with burning rate from 10kgs to 500kgs per hour and we always proposal customer send us their require details, like waste material, local site fuel and power supply, incinerator operation time, etc, so we can proposal right model or custom made with different structure or dimensions.
Incinerator Model YD-100 is a middle scale incineration machine for many different usage: for a middle hospital sickbed below 500 units, for all small or big size family pets (like Alaskan Malamute Dog), for community Municipal Solid Waste Incineration, etc. The primary combustion chamber volume is 1200Liters (1.2m3) and use diesel oil or natural gas fuel burner original from Italy.
Latest Post
Animal Incinerator
Basic Info.
Additional Info.
Product Description
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long lifetime. *according to order * High temperature, long lifetime of incinerator. * Free or minimal installation on site. *according to order * New Design for pet animal cremation company. * One year warranty on incinerator and components in stock. Is a major waste incinerator manufacturer in China. We are local manufacturer and among the greatest exporter of China. Pyrolytic incinerator equipment technical is primary waste treatment all of the planet, for Medical Waste, Animal Incineration, Pet cremation and other waste incinerators china, waste incinerators crematorium, waste incinerators equipment manufacturers, waste incinerators garden, waste load incineration, Waste substances with capacity of 50 kg/hr, strong wste. The capacity from 10kgs/Hr. To 500kgs/Hr. , up to 6ton per day. Presently, we provide different series for local client requirements and design upgraded incinerator with our leading technology. The updated design characteristic of our assortment of incinerators make them among the most cost effective in the world.
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| 1st. Chamber Temperature | 800–1000 degree | 800–1000 degree | 800–1000 degree | 800–1000 degree | 800–1000 degree |
| 2nd. Chamber Temperature | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree | 1000-1200 degree |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Small Scale Incinerator for Solid Waste
Basic Info.
Product Description
| Items | Specification | ||||
| Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
| Main Product List | Double Combustion Chamber | ||||
| Smoke Filter Chamber | |||||
| PLC Mode Control Case | |||||
| Stainless Steel Chimney | |||||
| Italy oil/gas burner: 02 units | |||||
| Oil Tank (if oil fuel) | |||||
Nanjing Clover Medical Technology Co., Ltd..
MSW Incinerator
Pets Crematorium
Basic Info.
Additional Info.
Product Description
The required circular Medical Waste Incinerator will be quoted according to Technical Specifications provided below: 1) A self-contained, gas gas, medical waste incinerator with a minimum burn rate capacity of 100 kg/day.
2) A medical waste incinerator shall be specifically designed by the manufacturer to eliminate all Bio-Hazard medical wastes.
3) At a minimum the device shall be sized to incinerate 2.0 kg/exam-room/24-hrs when being operated continuously for 12 hours daily, but no less than 100kg/day total.
4) The Incinerator shall be manually batch fed.
5) The incinerator fuel tank shall meet the following requirements: A) The tank shall be installed above ground and based on all the large medical waste incinerator, big mobile incinerator, large scale animal incinerator, large scale incinerators for medical waste disposal, fuel tank requirements in Section 1015 including secondary containment. B) The tank shall be sized to maintain a 14 day supply of diesel fuel
6) Manufacturer has to provide the following capacity calculations and all supporting information for the incinerator:
– The daily waste stream rate (kg/day or lbs/day) Minimum incinerator burn rate capacities – Minimum cure time for your refractory to avoid cracking to the refractory A comprehensive collection of the maintenance parts A minimum of 500 lbs of refractory for repairs A minimum of 1 gallon of hydraulic oil
7) The contractor shall provide 3 pricing options: Option 1: To Quote only for the Full System Option 2: To Quote the purchase price of Full System, and also the Installation Option 3: To give training to appropriate relevant staff according to the 'Operations and Maintenance. (Afghanistan)
| Items/Model | TS10(PLC) | TS20(PLC) | TS30(PLC) | TS50(PLC) | TS100(PLC) |
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Feed Capacity | 20kg | 40kg | 60kg | 100kg | 200 kg |
| Control Mode | PLC | PLC | PLC | PLC | PLC |
| Combustion Chamber | 100L | 210L | 330L | 560L | 1200L |
| Internal Dimensions | 50x50x40cm | 65x65x50cm | 75x75x60cm | 100x80x70cm | 120x100x100cm |
| Secondary Chamber | 50L | 110L | 180L | 280L | 600L |
| Smoke Filter Chamber | Yes | Yes | Yes | Yes | Yes |
| Feed Mode | Manual | Manual | Manual | Manual | Manual |
| Voltage | 220V | 220V | 220V | 220V | 220V |
| Power | 0.5Kw | 0.5Kw | 0.5Kw | 0.7Kw | 0.7Kw |
| Oil Consumption (kg/hour) | 5.4–12.6 | 7.8–16.3 | 10.2–20 | 12.1–24 | 14–28 |
| Gas Consumption (m3/hour) | 6.2–11.4 | 8–15.7 | 9.8–20 | 9.9–26.1 | 10–32.2 |
| Temperature Monitor | Yes | Yes | Yes | Yes | Yes |
| Temperature Protection | Yes | Yes | Yes | Yes | Yes |
| Oil Tank | 100L | 100L | 100L | 100L | 200L |
| Feed Door | 30x30cm | 45x40cm | 55x50cm | 70x55cm | 80x60cm |
| Chimney | 3Meter | 3Meter | 5Meter | 5Meter | 10Meter |
| Chimney Type | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel | Stainless Steel |
| 1st. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
| 2nd. Chamber Temperature | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree | 800degree–1000degree |
| Residency Time | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. | 2.0 Sec. |
| Gross Weight | 1500kg | 2200kg | 3000kg | 4500kg | 6000kg |
| External Dimensions | 140x90x120cm | 160x110x130cm | 175x120x140cm | 230x130x155cm | 260x150x180cm |
Medical Waste Incinerator Diesel and Gas Specification
Basic Info.
Product Description
Nanjing Clover Medical Technology Co., Ltd..
Key Features: * All versions with Dual combustion chamber. * Stainless Steel chimney/stack, long life. *according to sequence * High temperature, long life of incinerator. * Free or minimal installation on site. * High burn rate, from 10kgs to 500kgs per hour, up to 6ton per day. * PLC Control Plane. *based on order * New Design for pet animal cremation business. * One year warranty on incinerator and components in stock.
| Items | Specification | ||||
| Model | TS10(PLC) / TS20(PLC) / TS30(PLC) / TS50(PLC) / TS100(PLC) | ||||
| Burn Rate | 10 kg/hour | 20 kg/hour | 30 kg/hour | 50 kg/hour | 100 kg/hour |
| Main Product List | Double Combustion Chamber | ||||
| Smoke Filter Chamber | |||||
| PLC Mode Control Case | |||||
| Stainless Steel Chimney | |||||
| Italy oil/gas burner: 02 units | |||||
| Oil Tank (if oil fuel) | |||||
Program Scope: 1. Hospital& clinic: Iatric Waste, Infectious Waste, Dressing, Bio-Waste, Medicine. 2. Slaughter House &Pet Hospital &Farm: Dead Animal, Bio-Waste. 3. Community & Sea Port & Station: Municipal Solid Waste, etc. 4. Laboratories, Remote Locations, Disaster Relief Operations, Animal Cremation Company License No.,: 320105000138343













